background image

 

7.AWB 

1)  To  start  AWB,  take  an  image  of  a  white  subject  and  transmit  an    AWB  SART  command    under  the  following 

conditions: 

●The WB mode should be AWB. 

●The camera screen (a live image) should be on.  (The OSD PAGE data should be 00H.) 

●AWB,ABB,SHD should not be under execution.  (AUTO READ data should not be 01H,0BH,0FH) 

 

2)

 

For the AWB status (whether in progress or complete) and  the  final  result,  read  the  contents  of  AUTO  READ  by 

using the MEMORY DATA READ REQUEST(FF 03 FF FF) command. For the causes of errors, refer to the following: 

                NG 

 

: AWB will not be completed within a specified time. 

                CTEMP HIGH 

: Color temperature is too high. 

                CTEMP LOW 

: Color temperature is too low. 

                LEVEL HIGH 

: The level of the image in the area is too high. 

                LEVEL LOW 

: The level of the image in the area is too low. 

                NOT AVAILABLE : AWB START command has been transmitted when the conditions specified in 1) are unmet. 

 

 

8.ABB 

1)

To start ABB, transmit an ABB START command under the following conditions: 

●The camera screen (a live image) should be on.(The OSD PAGE data should be 00H.) 

●AWB,ABB,SHD should not be under execution.  (AUTO READ data should not be 01H,0BH,0FH.) 

 

2)

For  the  ABB  status  (whether  in  progress  or  complete)  and  the  final  result,  read  the  contents  of  AUTO  READ  by 

using  the  ABB  MEMORY  DATA  READ  REQUEST(FF  03  FF  FF)  command.  For  the  cause  of  errors,  refer  to  the 

following: 

                NG 

 

      : ABB will not be completed within a specified time. 

                    CLOSE LENS 

      : The lens iris is open. Close the lens iris. 

 

Содержание IK-HD1C

Страница 1: ...ynchronous Baud rate 9600 bps 19200 bps Data length 8 bits Parity None Start bit 1 bit Stop bit 1 bit Direction of transmission LSB first Handshake function None 2 Terminal names camera side Name Direction of signal TXD Camera to PC RXD PC to camera GND GND 3 Method of connection Camera PC RS 232C TXD RXD RXD TXD GND GND ...

Страница 2: ...d transmit a return code 15 01 FF FF Camera to PC PC to camera 1st byte 2nd byte 3rd byte 4th byte 100µS or more Command 4 1 Camera communications consist of receiving a four byte command code from the PC and then 4 Communication procedure communicating a four byte return code from the camera The same is true in the case of an overrun error or framing error About two seconds after such an error oc...

Страница 3: ...presetting does not change the baud rate setting All other items function in the same way as the presetting actions made by pressing the MENU DOWN and DATA DOWN simultaneously This returns the product to its initial settings 4BH 0DH FFH FFH KEY LOCK ON Functions in the same way as the KEY LOCK switch on the rear panel 4BH 0EH FFH FFH KEY LOCK OFF 4BH 11 H FFH FFH GAIN Functions in the same way as ...

Страница 4: ...eads the contents of the specified item 2 MEMORY DATA WRITE REQUEST 53 ADDRESS DATA L DATA H This function is used to rewrite the contents of items that can be configured by OSD two byte data For the contents of ADDRESS and DATA see 11 ADDRESS DATA 1 st byte 05H 53H This function rewrites the contents of the specified item During AWB while the data in AUTO READ is 01H the product will not accept t...

Страница 5: ... any of the following Command category Command item Camera status that causes a mode error Operation switch system DISP AWB ABB ASHD being executed PAGE AWB ABB ASHD being executed MENU UP Color bar screen on Camera screen on AWB ABB ASHD being executed MENU DOWN ditto DATA UP Color bar screen on Camera screen on AWB ABB ASHD being executed DATA DOWN ditto FILE Color bar screen on AWB ABB ASHD bei...

Страница 6: ...TEMP LOW Color temperature is too low LEVEL HIGH The level of the image in the area is too high LEVEL LOW The level of the image in the area is too low NOT AVAILABLE AWB START command has been transmitted when the conditions specified in 1 are unmet 8 ABB 1 To start ABB transmit an ABB START command under the following conditions The camera screen a live image should be on The OSD PAGE data should...

Страница 7: ...cessary exceeds the cameraʼs range so the maximum possible value is applied LEVEL HIGH The level of the image in the area is too high LEVEL LOW The level of the image in the area is too low SHD NG AUTO SHADING will not be completed within a specified number of times NOT AVALABLE ASHD START command has been transmitted when the conditions specified in 1 are unmet 10 Other The product will store the...

Страница 8: ...er the ratio is 10 Peak only SPEED 05H H 00H 13H 1 20 Adjusts the automatic shutter response speed The bigger the value is the faster the response is 00H PRESET A 01H PRESET B 02H PRESET C 03H PRESET D AREA 06H H 04H PRESET E Selects the available picture area in the automatic shutter mode PRESET A B C D E Specified range USER User setting range Setting area is available 00H OFF 01H 1 100S 02H 1 1...

Страница 9: ...0231H OFF Shutter speed 1 60 ...

Страница 10: ...n the master gain is manual 00H AWB 01H ATW MODE 30H H 02H MANUAL Sets the white balance mode 00H 3200K C TEMP 31H H 01H 5600K Sets a color temperature R PAINT 32H H F6H 00H 0AH 10 00 10 Sets the RED setting in AWB mode B PAINT 33H H F6H 00H 0AH 10 00 10 Sets the BLUE setting in AWB mode 00H PRESET A 01H PRESET B 02H PRESET C 03H PRESET D WHITE BALANCE AREA 34H H 04H PRESET E Sets in AWB mode PRES...

Страница 11: ...e RED setting in ATW mode ATW B PAINT 3CH H F6H 00H 0AH 10 0 10 Sets the BLUE setting in ATW mode AWB R DATA READ A0H H H Data read 201 2838 Reads R data in Auto White Balance Note This item can only read 1st byte 05H It can not be written 1st byte 53 WHITE BALANCE AWB B DATA READ A1H H H Data read 201 2838 Reads B data in Auto White Balance Note This item can only read 1st byte 05H It can not be ...

Страница 12: ...a correction setting ON OFF GAMMA 41H H F6H 00H 0AH 10 0 10 Gamma correction level setting DTLGAIN 44H H F9H 00H 07H 7 0 7 DTL gain setting M PED 46H H 9CH 00H 64H 100 0 100 Master pedestal setting 00H OFF PROCESS DNR 48H H 01H ON Digital noise reduction setting ON OFF ...

Страница 13: ... 51H H F1H 00H 0FH 15 0 15 Red hue setting R GAIN 52H H F1H 00H 0FH 15 0 15 Red gain setting G HUE 53H H F1H 00H 0FH 15 0 15 Green hue setting G GAIN 54H H F1H 00H 0FH 15 0 15 Green gain setting B HUE 55H H F1H 00H 0FH 15 0 15 Blue hue setting MATRIX B GAIN 56H H F1H 00H 0FH 15 0 15 Blue gain setting ...

Страница 14: ...tting Ye GAIN 58H H F1H 00H 0FH 15 0 15 Yellow gain setting Cy HUE 59H H F1H 00H 0FH 15 0 15 Cyan hue setting Cy GAIN 5AH H F1H 00H 0FH 15 0 15 Cyan gain setting Mg HUE 5BH H F1H 00H 0FH 15 0 15 Magenta hue setting MATRIX Mg GAIN 5CH H F1H 00H 0FH 15 0 15 Magenta gain setting ...

Страница 15: ... 128 0 127 Sets a correction value for cases when the shading correction mode is MANUAL RGB 00H G Only G signal output setting with SYNC SYNC 01H ALL ON All RGB output setting with SYNC 86H H 02H ALL OFF All RGB output setting without SYNC BAUD 00H 9600bps RATE 88H H 01H 19200bps Sets a baud rate for RS232C communications 00H ALL ON All output setting with OSD 01H Analog Only analog output setting...

Страница 16: ...Data Item Address H L Action 00H FILE A 01H FILE B 02H FILE C 03H FILE D SCENE FILE 90H H 04H FILE E Selects a scene file ...

Страница 17: ...B GAIN MAX 07H The final result of AWB is rejected LEVEL HIGH 08H The final result of AWB is rejected LEVEL LOW 09H The final result of AWB is rejected NOT AVAILABLE 0AH The final result of AWB is rejected 0BH ABB in progress 0CH The final result of ABB is accepted 0DH The final result of ABB is rejected 0EH The final result of ABB is rejected LENS OPEN 0FH AUTO SHADING in progress 10H The final r...

Страница 18: ...F a live image 01H INDEX 02H SHUTTER 03H GAIN 04H WHITE BALANCE 05H PROCESS 06H MATRIX 07H SYNC 08H OPTION OSD PAGE 04H FFH FFH COLOR BAR POINT 05H FFH 00H 0CH 1st ITEM to 13th ITEM The position of for the each MENU 1st to 13th from the top ...