12
.ADDRESS & DATA (1st byte=FFH)
Data
Item
Address
H
L
Action
GAIN READ
01H
FFH
00H
↓
12H
00dB
↓
18dB
Master gain
00H
KEY LOCK ON
KEY LOCK READ
02H
FFH
01H
KEY LOCK OFF
Key lock mode. (It may differ from the switch position by the remote settings.)
01H
AWB in progress.
02H
The final result of AWB is accepted.
03H
The final result of AWB is rejected. C.TEMP HIGH(R GAIN MAX)
04H
The final result of AWB is rejected. C.TEMP HIGH(B GAIN MIN)
05H
The final result of AWB is rejected. C.TEMP LOW(R GAIN MIN)
06H
The final result of AWB is rejected. C.TEMP LOW(B GAIN MAX)
07H
The final result of AWB is rejected. LEVEL HIGH
08H
The final result of AWB is rejected. LEVEL LOW
09H
The final result of AWB is rejected. NOT AVAILABLE
0AH
The final result of AWB is rejected.
0BH
ABB in progress.
0CH
The final result of ABB is accepted.
0DH
The final result of ABB is rejected.
0EH
The final result of ABB is rejected. LENS OPEN
0FH
AUTO SHADING in progress.
10H
The final result of AUTO SHADING is accepted.
11H
The final result of AUTO SHADING is rejected.
12H
The final result of AUTO SHADING is accepted. LIMIT
13H
The final result of AUTO SHADING is rejected. LEVEL HIGH
14H
The final result of AUTO SHADING is rejected. LEVEL LOW
AUTO READ
03H
FFH
15H
The final result of AUTO SHADING is rejected. NOT AVAILABLE