264
H9 ASD Installation and Operation Manual
Table 19. 460 Volt UL Type-1/IP-20 Chassis standard ratings table.
Model
Number
VT130H9U
100% Output
Current
Continuous
Overload Current
120% for 60
Seconds
Input Voltage
3-Ph 50/60
± 2 Hz
Output Voltage
3-Ph Variable
Frequency
Typical
Motor HP
4055
7.6 A
9.0 A
380 – 480 VAC
(±10%)
Input Voltage
Level (Max.)
5.0
4080
11 A
13 A
7.5
4110
14 A
17 A
10
4160
21 A
25 A
15
4220
27 A
32 A
20
4270
34 A
41 A
25
4330
40 A
48 A
30
4400
52 A
62 A
40
4500
65 A
78 A
50
4600
77 A
92 A
60
4750
96 A
115 A
75
410K
124 A
149 A
100
412K
156 A
187 A
125
415K
180 A
216 A
150
420K
240 A
288 A
200
425K
302 A
362 A
250
430K
361 A
433 A
300
435K
414 A
497 A
350
440K
477 A
572 A
400
Содержание H9
Страница 1: ...H9 ADJUSTABLE SPEED DRIVE Installation and Operation Manual ...
Страница 2: ......
Страница 267: ...H9 ASD Installation and Operation Manual 259 Figure 34 See Tables 16 and 17 for actual dimensions ...
Страница 270: ...262 H9 ASD Installation and Operation Manual Figure 37 See Table 17 for the associated device Dimensions are in in cm ...