230
H9 ASD Installation and Operation Manual
Monitor Output Function 21
Program
⇒
My Function
⇒
My Function Monitor
This parameter plays a role in the setup of the My Function feature by
establishing the function that is to be recorded and output as the Peak,
Minimum, or Average value as selected at parameter
F968
.
Select the Monitor Display Input Setting number from
Table 10 on pg. 243
to
output the corresponding function.
Use the Communication Number if operating using communications.
See the My Function Instruction Manual (P/N 58692) for a complete
description of the setup requirements and operational information of the
Monitor Output Function parameter.
Direct Access Number — F967
Parameter Type — Selection List
Factory Default — 2000
Changeable During Run — Yes
Monitor Output Function Command 21
Program
⇒
My Function
⇒
My Function Monitor
This parameter plays a role in the setup of the My Function feature by allowing
the user to select the Peak, Minimum, or Normal (Avg.) value of the
parameter
F967
selection to be recorded and output as a monitored function.
Settings:
0 — Normal
1 — Peak
2 — Minimum
See the My Function Instruction Manual (P/N 58692) for a complete
description of the setup requirements and operational information of the
Monitor Output Function parameter.
Direct Access Number — F968
Parameter Type — Selection List
Factory Default — Normal
Changeable During Run — Yes
Monitor Output Function 31
Program
⇒
My Function
⇒
My Function Monitor
This parameter plays a role in the setup of the My Function feature by
establishing the function that is to be recorded and output as the Peak,
Minimum, or Average value as selected at parameter
F970
.
Select the Monitor Display Input Setting number from
Table 10 on pg. 243
to
output the corresponding function.
Use the Communication Number if operating using communications.
See the My Function Instruction Manual (P/N 58692) for a complete
description of the setup requirements and operational information of the
Monitor Output Function parameter.
Direct Access Number — F969
Parameter Type — Selection List
Factory Default — 2000
Changeable During Run — Yes