105
Toshiba
10
Hydro unit and Outdoor Unit Settings
Hydro unit
1. Hydro unit Setting
1-1. Setting switch names and positions
1-2. SW02 (System switching 1)
1-3. SW10 (Pump switching)
1-4. SW11 (Heater Yes/No switching)
1-5. SW12 (System switching 2)
1-6. SW13 (System switching 3)
SW02
Switching details
Factory setting
Remarks
02_1
–
–
OFF
02_2
–
–
OFF
02_3
–
–
OFF
02_4
Room thermostat
No
OFF
SW10
Switching details
Factory setting
Remarks
10_1
–
–
OFF
10_2
–
–
OFF
10_3
Enhanced pump2 Interlock Yes/No
Yes
OFF
10_4
–
–
OFF
SW11
Switching details
Factory setting
Remarks
11_1
Internal backup heater Energized Yes/No
Energized
OFF
11_2
Hot water cylinder heater Energized Yes/No
Energized
OFF
11_3
Booster heater Energized Yes/No
Energized
OFF
11_4
–
–
OFF
SW12
Switching details
Factory setting
Remarks
12_1
Hot water supply
Yes
OFF
12_2
ZONE1
Yes
OFF
12_3
ZONE2
No
OFF
12_4
–
–
OFF
SW13
Switching details
Factory setting
Remarks
13_1
3WV SPST/SPSD Specification switching
SPST
OFF
13_2
Boiler placement
No
OFF
13_3
Auto Restart of power outage
Yes
OFF
13_4
–
–
OFF
SW10
SW01
SW02
SW11
SW12
SW13
SW07