CDE0
Finisher related ser-
vice call
Paddle motor abnormality: The paddle motor is not
rotating or the paddle is not rotating normally. [MJ-
1101]
P. 6-86
CE00
Communication error between finisher and punch
unit: Communication error between finisher control-
ler PC board and punch controller PC board
[MJ-1030 (when MJ-6004 is installed)]
[MJ-1101 (when MJ-6101 is installed)]
P. 6-86
CE10
Image control related
service call
Image quality sensor abnormality (OFF level): The
output value of this sensor is out of a specified
range when sensor light source is OFF.
P. 6-93
CE20
Image quality sensor abnormality (no pattern level):
The output value of this sensor is out of a specified
range when the image quality control test pattern is
not formed.
P. 6-94
CE40
Image quality control test pattern abnormality: The
test pattern is not formed normally.
P. 6-96
CE50
Image control related
service call
Temperature/humidity sensor abnormality: The out-
put value of this sensor is out of a specified range.
P. 6-98
CE60
Drum thermistor-Y abnormality: The output value of
the drum thermistor-Y is out of a specified range.
P. 6-98
CE70
Drum drive switching abnormality: The drum
switching detection sensor (S19) is not turned ON
after the drum motor was rotated for a specified
period of time.
P. 6-99
CE71
Drum phase adjustment abnormality: Drum phase
sensors (Color drum phase sensor (S43) and K
drum phase sensor (S44)) are not turned ON after
the drum motor was rotated for a specified period of
time.
P. 6-100
CE90
Drum thermistor-K abnormality: The output value of
the drum thermistor-K is out of a specified range.
P. 6-98
CEC0
Copy process related
service call
2nd transfer roller position detection abnormality:
The 2nd transfer roller does not contact/release
normally.
P. 6-105
CF10
Finisher related ser-
vice call
Communication module SRAM reading failure.
[MJ-1101]
P. 6-87
CF90
Laser optical unit
related service call
Laser optical unit shutter abnormality.
P. 6-70
F070
Communication
related service call
Communication error between System-CPU and
Engine-CPU
P. 6-64
F090
Circuit related service
call
SRAM abnormality on the SYS board
P. 6-66
F100
Other service call
HDD format error: HDD cannot be initialized nor-
mally.
P. 6-106
F101
HDD unmounted: Connection of HDD cannot be
detected.
P. 6-106
F102
HDD start error: HDD cannot become ‘Ready’ state.
P. 6-106
F103
HDD transfer time-out: Reading/writing cannot be
performed in the specified period of time.
P. 6-106
F104
HDD data error: Abnormality is detected in the data
of HDD.
P. 6-106
F105
HDD other error
P. 6-106
F106
Point and Print partition damage
P. 6-106
F107
/BOX partition damage
P. 6-106
F108
/SHA partition damage
P. 6-106
Error code
Classification
Contents
Troubleshooting
Содержание e-STUDIO2820C
Страница 6: ......
Страница 12: ...e STUDIO2820C 2830C 3520C 3530C 4520C 2008 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 6 ...
Страница 210: ...e STUDIO2820C 2830C 3520C 3530C 4520C 2008 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 78 ...
Страница 230: ...e STUDIO2820C 2830C 3520C 3530C 4520C 2008 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 4 20 ...
Страница 266: ...e STUDIO2820C 2830C 3520C 3530C 4520C 2008 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 5 36 ...
Страница 485: ......
Страница 486: ......