e-STUDIO2820C/2830C/3520C/3530C/4520C
© 2008 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 20
[E] Primary scanning data laser writing start position at duplexing
Note:
Make sure the first line of the grid pattern is printed out since the line is occasionally vanished.
[E-1]
Adjustment for long-sized paper
(1) While pressing [0] and [5] simultaneously, turn the power ON.
→
(Adjustment Mode)
(2) Press [3]
→
[FAX]. (A grid pattern with 10 mm squares is printed out. Use A3/LD from the 2nd
drawer.)
(3) Check the grid pattern on the test print and measure the distance E from the left edge of the
paper to the 6th line of the grid pattern.
(4) Check if the distance E is within 52±0.5 mm.
(5) If not, use the following procedure to change values and measure the distance E again.
<Procedure>
(Adjustment Mode)
→
(Key in the code [498])
→
[START]
→
[0]
→
[START]
→
(Key in a value (acceptable values: 0 to 255))
→
[ENTER] or [INTERRUPT] (Stored in memory)
→
"100% A" is displayed.
→
Press [3]
→
[FAX]
→
(A grid pattern is printed out.)
*The larger the adjustment value is, the longer the distance E becomes (approx. 0.04 mm/step).
[E-2]
Adjustment for short-sized paper
(1) While pressing [0] and [5] simultaneously, turn the power ON.
→
(Adjustment Mode)
(2) Press [3]
→
[FAX]. (A grid pattern with 10 mm squares is printed out. Use A4/LT from the 1st
drawer.)
(3) Check the grid pattern on the test print and measure the distance E from the left edge of the
paper to the 6th line of the grid pattern.
(4) Check if the distance E is within 52±0.5 mm.
(5) If not, use the following procedure to change values and measure the distance E again.
<Procedure>
(Adjustment Mode)
→
(Key in the code [498])
→
[START]
→
[1]
→
[START]
→
(Key in a value (acceptable values: 0 to 255))
→
[ENTER] or [INTERRUPT] (Stored in memory)
→
"100% A" is displayed
→
Press [3]
→
[FAX]
→
(A grid pattern is printed out.)
*The larger the adjustment value is, the longer the distance E becomes (approx. 0.04 mm/step).
<Adjustment procedure summarization for A to E>
[0] [5] [Power ON]
→
[98] ([3](05-445, 498) for duplexing)
→
[FAX]
A: 05-401 (2nd drawer, A3/LD)
→
200±0.5 mm (0.08 mm/step)
B: 05-411 (2nd drawer, A3/LD)
→
52±0.5 mm (0.04 mm/step)
→
Key in the same value for 05-410.
C: 05-487-0 to 8 (2nd drawer, A3/LD)
→
200±0.5 mm (0.09 mm/step)
D: 05-408 (2nd drawer, A3/LD)
→
52±0.5 mm (0.15 mm/step)
05-440 (1st drawer, A4/LT)
05-441 (2nd drawer, A3/LD)
05-444 (PFP upper drawer, A4/LT)
05-428 (PFP lower drawer, A4/LT)
05-442 (Bypass feed, A4/LT)
05-445 (Duplexing, A3/LD)
E: 05-498-0 (2nd drawer, A3/LD),
→
52±0.5 mm (0.04 mm/step)
05-498-1 (1st drawer, A4/LT)
Содержание e-STUDIO2820C
Страница 6: ......
Страница 12: ...e STUDIO2820C 2830C 3520C 3530C 4520C 2008 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 6 ...
Страница 210: ...e STUDIO2820C 2830C 3520C 3530C 4520C 2008 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 78 ...
Страница 230: ...e STUDIO2820C 2830C 3520C 3530C 4520C 2008 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 4 20 ...
Страница 266: ...e STUDIO2820C 2830C 3520C 3530C 4520C 2008 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 5 36 ...
Страница 485: ......
Страница 486: ......