© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO165/167/205/207/237
ADJUSTMENT
3 - 7
3
3.2.3
Printer related adjustment
[A] Reproduction ratio of primary scanning direction (Fine adjustment of polygonal motor rota-
tion speed (Printer))
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode)
(2) Press [1] [FAX] [Drawer number] (Select from 0: bypass, 1: drawer, 2: PFU, 3: PFP upper
drawer or 4: PFP lower drawer.) [START]. (A grid pattern with 10 mm squares is printed out.
Use A3/LD from standard drawer of the equipment.)
(3) Check the grid pattern on the test chart printed out and measure the distance A from the 1st line
to the 21st line of the grid pattern.
(4) Check if the distance A is within 200±0.5 mm.
(5) If not, use the following procedure to change values and measure the distance A again.
(Adjustment Mode) (Key in code [401]) [ENTER]
(Key in a value (acceptable values: 0 to 255))
[ENTER] (Stored in memory) [CANCEL] “MC” is displayed
Press [1] [FAX]
Press [Drawer number] [START]
(A grid pattern is printed out.)
* The larger the adjustment value is, the longer the distance A becomes (approx. 0.125 mm/
step).
[B] Primary scanning data laser writing start position (Printer)
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode)
(2) Press [1] [FAX] [Drawer number] (Select from 0: bypass, 1: drawer, 2: PFU, 3: PFP upper
drawer or 4: PFP lower drawer.) [START]. (A grid pattern with 10 mm squares is printed out.
Use A3/LD from standard drawer of the equipment.)
(3) Check the grid pattern on the test chart printed out and measure the distance B from the left edge
of the paper to the 6th line of the grid pattern.
(4) Check if the distance B is within 52±0.5 mm.
(5) If not, use the following procedure to change values and measure the distance B again.
(Adjustment Mode) (Key in the code [411]) [ENTER]
(Key in a value (acceptable values: 0 to 255))
[ENTER] (Stored in memory) [CANCEL] “MC” is displayed
Press [1] [FAX]
Press [Drawer number] [START]
(A grid pattern is printed out.)
* The larger the adjustment value is, the longer the distance B becomes (approx. 0.05 mm/
step).
06/04
Содержание e-STUDIO165
Страница 8: ...e STUDIO165 167 205 207 237 2006 2008 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Страница 10: ......
Страница 200: ...e STUDIO165 167 205 207 237 2006 2008 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 62 ...
Страница 300: ...e STUDIO165 167 205 207 237 2006 2008 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 7 4 ...
Страница 308: ...e STUDIO165 167 205 207 237 2006 2008 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION 9 2 ...
Страница 312: ......
Страница 313: ......