e-STUDIO350/352/353/450/452/453
DRUM RELATED SECTION
11
-
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
(11) Remove 1 screw and stand the developer
unit guide aside.
Fig. 11-637
(12) Remove 2 screws and take off the middle
fan duct.
Fig. 11-638
(13) Disconnect 1 connector and remove 2
screws and take off the middle fan.
Note:
When installing, pay attention to the direction of
the wind from the fan.
Fig. 11-639
[K] Temperature / Humidity sensor
(1) Open the front cover.
(2) Take off the receiving tray ( Chapter 2.5.1
[H]).
(3) Disconnect 1 connector and remove 1
screw. Then take off the temperature / hu-
midity sensor with the whole cover.
Fig. 11-640