Fig. 9-450
(13) Disconnect 3 connectors of the drive gear
unit.
Connector
Connector
Fig. 9-453
Fig. 9-452
Fig. 9-451
(14) Disconnect 2 connectors wired from the
drive gear unit.
(15) Remove 5 screws and take off the drive
gear unit.
(16) Remove the E-ring and the bushing of the
registration roller (1 pc. each).
(17) Remove the E-ring and the bushing on the
front side and slide the registration roller
(rubber) to the rear side to take it off.
Connector
Drive gear unit
Screw
Screw
Bushing
E-ring
E-ring
Registration
roller (rubber)
Bushing
Содержание e-Studio 350
Страница 20: ...1 12 2003 2008 TOSHIBA TEC CORPORATION All rights reserved 1 e STUDIO350 352 353 450 452 453 SPECIFICATIONS ...
Страница 108: ...4 16 4 e STUDIO350 352 353 450 452 453 GENERAL OPERATION 2003 2008 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 146: ...6 6 24 e STUDIO350 352 353 450 452 453 SCANNER 2003 2008 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 202: ...10 10 e STUDIO350 352 353 450 452 453 DRIVE SYSTEM 2003 2008 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 238: ...12 16 12 e STUDIO350 352 353 450 452 453 DEVELOPMENT SYSTEM 2003 2008 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 284: ...14 20 14 e STUDIO350 352 353 450 452 453 AUTOMATIC DUPLEXING UNIT 2003 2008 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 292: ...15 15 e STUDIO350 352 353 450 452 453 POWER SUPPLY UNIT 2003 2008 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 301: ......
Страница 302: ......