© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO163/166/203/206
ADJUSTMENT
3 - 7
3
3.2.3
Printer related adjustment
[A] Reproduction ratio of primary scanning direction (Fine adjustment of polygonal motor rota-
tion speed (Printer))
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
#
(Adjustment Mode)
(2)
Press [1]
#
[INTERRUPT]
#
[Drawer number] (Select from 0: bypass, 1: drawer or 2: PFU.)
#
[START]. (A grid pattern with 10 mm squares is printed out. Use A3/LD from standard drawer of
the equipment.)
(3)
Check the grid pattern on the test chart printed out and measure the distance A from the 1st line
to the 21st line of the grid pattern.
(4)
Check if the distance A is within 200±0.5 mm.
(5)
If not, use the following procedure to change values and measure the distance A again.
(Adjustment Mode)
#
(Key in code [401])
#
[START]
#
(Key in a value (acceptable values: 0 to 255))
#
[INTERRUPT] (Stored in memory)
#
“AJ” is displayed
#
Press [1]
#
[INTERRUPT]
#!
Press [Drawer number]
#
[START]
#
(A grid pattern is printed out.)
*The larger the adjustment value is, the longer the distance A becomes (approx. 0.125 mm/step).
[B] Primary scanning data laser writing start position (Printer)
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
#
(Adjustment Mode)
(2)
Press [1]
#
[INTERRUPT]
#
[Drawer number] (Select from 0: bypass, 1: drawer or 2: PFU.)
#
[START]. (A grid pattern with 10 mm squares is printed out. Use A3/LD from standard drawer of
the equipment.)
(3)
Check the grid pattern on the test chart printed out and measure the distance B from the left edge
of the paper to the 6th line of the grid pattern.
(4)
Check if the distance B is within 52±0.5 mm.
(5)
If not, use the following procedure to change values and measure the distance B again.
(Adjustment Mode)
#
(Key in the code [411])
#
[START]
#
(Key in a value (acceptable values: 0 to 255))
#
[INTERRUPT] (Stored in memory)
#
“AJ” is displayed
#
Press [1]
#
[INTERRUPT]
#!
Press [Drawer number]
#
[START]
#
(A grid pattern is printed out.)
*The larger the adjustment value is, the longer the distance B becomes (approx. 0.05 mm/step).
06/04
Содержание e-STUDIO 163
Страница 6: ......
Страница 10: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Страница 12: ......
Страница 140: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Страница 158: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 18 ...
Страница 206: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 48 ...
Страница 228: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 7 4 ...
Страница 230: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION 8 2 ...
Страница 234: ......
Страница 235: ......