© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO163/166/203/206
FIRMWARE UPDATING
6 - 5
6
[B] Confirmation of the updated data
After the updating is completed, check each data version in the Setting Mode (08) to confirm that the
data was overwritten properly.
08-900: System ROM version
06/02
Содержание e-STUDIO 163
Страница 6: ......
Страница 10: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Страница 12: ......
Страница 140: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Страница 158: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 18 ...
Страница 206: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 48 ...
Страница 228: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 7 4 ...
Страница 230: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION 8 2 ...
Страница 234: ......
Страница 235: ......