e-STUDIO163/166/203/206
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 42
3.9
Adjustment of Developer Unit
3.9.1
Doctor-to-sleeve gap
Adjustment tool to use: Doctor-sleeve jig
<Procedure>
(1)
Perform the adjustment code “05-280”.
(2)
Take out the process unit from the equipment.
(3)
Take out the developer unit from the process unit.
(4)
Remove 2 screws and take off the developer
unit upper cover and discharge the devel-
oper material.
Note:
Note:
Discharge the developer material from the
rear side, being careful not to let it be scat-
tered on the gear.
Fig. 3-31
(5)
Turn the adjustment screw to widen the gap
so that the jig can be inserted in it.
(Turning the screw clockwise widens the
gap)
Fig. 3-32
Developer
unit upper cover
Screw
Содержание e-STUDIO 163
Страница 6: ......
Страница 10: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Страница 12: ......
Страница 140: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Страница 158: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 4 18 ...
Страница 206: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved TROUBLESHOOTING 5 48 ...
Страница 228: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 7 4 ...
Страница 230: ...e STUDIO163 166 203 206 2005 2008 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION 8 2 ...
Страница 234: ......
Страница 235: ......