1600/2000/2500 TROUBLESHOOTING
4 - 24
December 2000 © TOSHIBA TEC
4.1.6 Paper transporting jam at the RADF
E71
Original feeding jam at the feeding area of RADF
When original is left inside the RADF, remove it. If this error occurs frequently, the following
items should be checked.
[Two or more originals are fed simultaneously.]
Have too many originals been placed?
Reset the originals, following the specification.
Are the original sheets curled or folded too much?
Flatten and reset the originals.
Are different-size originals placed together?
Set only one-size originals.
Is the separation roller stained?
Clean the separation roller.
[The original does not reach the feed roller.]
Does the paper thickness satisfy the specifications?
Reset the originals, following the specification.
Is the pickup roller, feed roller or separation roller stained?
Clean the roller.
Is the transporting force of the pickup roller, feed roller or separation roller insufficient?
Replace the rollers.
YES
NO
YES
NO
YES
NO
YES
NO
YES
YES
NO
YES