December 2000 © TOSHIBA TEC
4 - 15
1600/2000/2500 TROUBLESHOOTING
Near the PFP upper transport roller
Is the PFP clutch working? (using the test mode 10, Output Test, CODE 225)
1. Check if each connector between the PFP clutch and the PFP PWA
(CN244) is disconnected.
2. Check if each connector between the PFP PWA (CN241) and the PFC
PWA (CN206) is disconnected.
3. Check if each connector between the PFC PWA (CN201) and the relay
PWA (CN36) is disconnected.
4. Check if each connector pin is removed or the harness is broken.
5. Check if any conductor pattern on the PFP, PFC, relay and main PWA
is open- or short-circuited.
6. Replace the PFP clutch.
7. Replace the PFP PWA.
8. Replace the PFC PWA.
9. Replace the relay PWA.
10. Replace the main PWA.
Check to see if there are any foreign obstacles on the recording paper path.
YES
NO