E6581737
- 18 -
3.4.5.3.
Instance 100/150 - Toshiba Specific (4 bytes, parameter
c203
= 2)
Byte
Bit 7
Bit 6
Bit 5
Bit 4 Bit
3 Bit
2 Bit
1 Bit
0
0
DC braking
ACC1/
ACC2
PI off
THR2
Preset
Speed4
Preset
Speed3
Preset
Speed2
Preset
Speed1
1
Command
link *
Frequency
link *
Reset trip
Emergency
stop
Free run
(ST)
Run/stop
Forward/
Reverse
Jog
2
Drive Reference Speed Hz (Low byte) **
3
Drive Reference Speed Hz (High byte) **
Fig. 5 Output Instance 100 Layout
Byte
Bit 7
Bit 6
Bit 5
Bit 4 Bit
3 Bit
2 Bit
1 Bit
0
0
DC braking
ACC2
PI
THR 2
(VF2+tH2)
-
ALARM
(fc91)
EMG FL
1
-
READY
without
ST/RUN
READY
with
ST/ RUN
Emergency
stop
Free run
(ST)
Run/Stop
Forward /
Reverse
Jog
2
Drive Actual Speed Hz (Low byte)
3
Drive Actual Speed Hz (High byte)
Fig. 6 Input Instance 150 Layout
* Bit 7 and 6 of the instance 100 byte 1 are defined as follows.
Bit 7 (Command link) ...... When “0” is set, the other command does not work except bit 4 and 3 of instance 100
byte 1, Run/Stop is according to setup of the VF-MB1/S15 parameter
cmod
.
Bit 6 (Frequency link)...... When “1” is set, Drive Reference Speed is according to the value of bytes 2 and 3.
When “0” is set, Drive Reference Speed is according to setup of the VF-MB1/S15
parameter
fmod
.
**
Drive Reference Speed
is set up by 0.01Hz unit and the hexadecimal number.
For example, when "Frequency reference" is set up to 60Hz, since the minimum unit is 0.01Hz,
60 / 0.01 = 6000 = 0x1770 (Hex.)