75 / 92
Copyright © 2016 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/en/
D4253386C
- Load a user setting at the time of start-up
Set the following value to “UserSetDefault” register. The setting value is Enumeration type.
The camera loads user setting from the channel selected in “UserSetDefault” register and applies them at
the time of next start-up.
setting value
Description
Default
- White balance unadjusted.
- DPC feature is not set.
- Other features similar to the initial factory setting.
UserSet1 (*)
Memory channel 1 for user setting.
Following features are adjusted.
- White balance
- DPC feature ON in the defective pixel coordinates already set.
UserSet2~15
Select memory channel 2 to 15 for user setting.
* initial factory setting
● Note
“UserSetDefault” register value is stored to non-volatile memory when “UserSetSave” is executed.
Thus, “UserSetSelector” shall be set other than “Default” in advance.