72 / 92
Copyright © 2016 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/en/
D4253386C
LUTControl
This function allows you to apply the
arbitrary
LUT(input: 12it, output: 12bit) to the output images.
example of LUT setting
● Registers
Register
Visibility
Access
Description
LUTEnable
Beginner
R/W
Sets the activation of LUT function.
LUTIndex
Beginner
R/W
Sets the input level of LUT.
LUTValue
Beginner
R/W
Sets the output level of LUT.
● Setting
- Set the activation of LUT
Set the following value to “LUTEnable” register. The setting value is Boolean type.
setting value
function
OFF (*)
Inactive
ON
Active
* initial factory setting
- Set the input/output value of LUT
Set the fol
lowing value to “LUTIndex”, “LUTValue” registers. These setting values are Integer type.
“LUTIndex” register value is input level of LUT, and “LUTValue” register value is output level of LUT.
LUTIndex / LUTValue
setting value
Minimum
(*)
0
Maximum
4095
* initial factory setting
● Note
Output
luminance
Input
luminance
Binarization