INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
EO15-33002
3. Ribbon Saving Module: B-SX908-R-QM-R
3- 5
12. Insert piled 12 pieces of tag paper (0.16-mm thick, I-BEST-S is recommended.) between the print head
and the platen. Then turn the head lever to the LOCK position.
13. Fully push the head up link to the direction indicated by the arrow 1. Push the solenoid toward the
head up link as indicated by the arrow 2, then secure the solenoid with the two SM-4x8 screws.
Solenoid (L)
Solenoid (R)
Head Lever
Tag Paper
LOCK Position
Head Up Link
Head Up
Link
1
2
SM-4x8 Screw
1
2
SM-4x8 Screw
Solenoid (L)
Solenoid (R)