3
Printer
Operation
Media
Sensor
Calibration
17
3
Printer
Operation
This
chapter
provides
information
about
printer
operation.
3.1
Media
Sensor
Calibration
You
will
want
the
printer
to
work
properly
before
starting
your
jobs.
To
do
this,
you
need
to
calibrate
the
media
sensor.
Toshiba
B
‐
FV4D
provides
transmissive
and
reflective
sensor
calibration.
Take
the
following
steps
to
use
them.
1.
Make
sure
the
media
is
properly
loaded,
the
module
is
closed,
and
the
printer’s
power
switch
is
set
to
the
OFF
position.
2.
Press
and
hold
the
FEED
button,
and
turn
on
the
printer.
3.
Both
status
lights
glow
solid
orange
for
a
few
seconds.
Next,
they
turn
to
green
shortly,
and
then
turn
to
other
colors.
Do
one
of
the
following
to
select
the
sensor:
If
you
want
to
calibrate
the
transmissive
sensor,
when
LED
1
turns
to
green
and
LED
2
turns
to
red,
release
the
FEED
button
immediately.
If
you
want
to
calibrate
the
reflective
sensor,
when
LED
1
turns
to
green
and
LED
2
turns
to
orange,
release
the
FEED
button
immediately.
4.
Press
the
FEED
button.
The
media
calibration
is
complete
after
the
printer
feeds
3
‐
4
labels
and
stops.
Содержание B-FV4D-GS12-QM-R
Страница 12: ...1 Introduction Understanding You Printer 3 1 3 Understanding Your Printer 1 3 1 Perspective View ...
Страница 13: ...1 Introduction Understanding You Printer 4 1 3 2 Back View Optional Interfaces ...
Страница 14: ...1 Introduction Understanding You Printer 5 1 3 3 Interior View ...
Страница 28: ...3 Printer Operation Self Test and Dump Mode 19 ...
Страница 44: ...5 Troubleshooting Media Issues 35 ...
Страница 51: ...6 Specifications Bar Code 42 ...