59 / 88
Copyright © 2012 - 2015 TOSHIBA TELI CORPORATION, All rights reserved. http://www.toshiba-teli.co.jp/index.htm
D4211908G
TimerControl
This section describes TimerControl category for the BG series.
This camera series is able to generate Timer0Active signal, derived from exposure start, by register setting.
This signal can be used as strobe control signal.
EXT_TRIG
Exposure
TIMER0 ACTIVE
Delay
Duration
* ActiveLow
EXPOSURE ACTIVE
Fig. Timer0Active
● Registers
Register
Visibility
Access
Description
TimerSelector
Expert
R
Returns the name of the timer that selected.
TimerDuration
Expert
R/W
Sets the width of Timer0Active signal.
TimerDelay
Expert
R/W
Sets the delay of Timer0Active signal.
TimerTriggerSource
Expert
R
Returns the timing that is the basic of the timer
● Setting
- Set the width of Timer0Active pulse
Set the following value to “TimerDuration” register. Setting value is Float type.
TimerDuration
Pulse width
Minimun (*)
0.00[μs]
Maximum
2000000
.00[μs]
* initial factory setting