85 / 88
Copyright © 2012 - 2015 TOSHIBA TELI CORPORATION, All rights reserved. http://www.toshiba-teli.co.jp/index.htm
D4211908G
- Set a ExposureValue of ALC operation
Set the following value to “ALCExposureValue” register. Setting value is Float type.
When set
“ALCExposureValue” register, add a correction value for a convergence value.
ExposureValue
setting value
Minimum
-2.00 [eV]
Maximum
+2.00 [eV]
* initial factory setting = 0.00 [eV]
F
inal convergence value by setting “ALCExposureValue” register is determined by the following formula.
Final convergence value = ReferenceLuminance x 2
ExposureValue
- Set a tolerance range of ALC operation
Set the following value to “ALCTolerance” register. Setting value is Float type.
Set convergence tolerance level for the ReferenceLuminance. When tolerance level is small, convergence
level become more accurate, but it takes longer time to converge.
Tolerance
setting value
Minimum
0.00 [%]
Maximum
50.00 [%]
* initial factory setting = 1.00 [%]
- Set a value of feedback fraction of ALC operation
Set the following value to “ALCThrottle” register. Setting value is Float type.
Throttle
setting value
Minimum
1.00 [%]
Maximum
100.00 [%]
* initial factory setting = 75.00 [%]
- Set the lock of ALC operation
Set the following value to “ALCLock” register. The setting value is Boolean type.
You can lock ALC operation by using this function.
setting value
Activation
FALSE (*)
inactive
TRUE
active
* initial factory setting