56 / 88
Copyright © 2012 - 2015 TOSHIBA TELI CORPORATION, All rights reserved. http://www.toshiba-teli.co.jp/index.htm
D4211908G
● Setting
- Selects exposure control mode
Set the following value to “ExposureMode” register. Setting value is Enumeration type.
setting value
Manual exposure mode
Timed (*)
“ExposureTime” register control
TriggerWidth
Trigger pulse width control
* initial factory setting
In Normal Shutter mode, the exposure time is determined by
“ExposureTime” register value regardless of
“ExposureMode” register setting.
- Sets exposure time (timed mode only)
Set the following value to “ExposureTime” register. Setting value is Float type.
Set the exposure time of Normal Shutter mode, and Random Trigger Shutter -Timed mode operation.
Model
BG030 /
BG030C
BG031
BG080
BG130 /
BG130C
BG202 /
BG202C
ExposureTime (*)
8000 [
μs]
8000 [
μs]
25000 [
μs]
33333 [
μs]
50000 [
μs]
ExposureTimeMin
10 [
μs]
10 [
μs]
30 [
μs]
30 [
μs]
30 [
μs]
ExposureTimeMax
16000000 [
μs]
* initial factory setting
- Set auto exposure
Set the following value to “ExposureAuto” register. Setting value is Enumeration type.
Select the exposure control.
setting value
function
Off (*)
Manual Exposure control
On
Auto Exposure control
* initial factory setting
● Note