-17-
No
LCD Message
(English)
LEDIndic
ation
Printer Status
Recovera
ble by the
[PAUSE]
key
Yes/No
Acceptan
ce of
Status
Request
and
Reset
Comman
ds
Yes/No
STATUS
25
SYNTAX ERROR
(Command error)(*3)
△
A command error has occurred while
analyzing the command.
Yes
Yes
26 LABEL PRESENT
Wait for Peel-off label
-
Yes
27
SSP AUTH
FAILED
○
Bluetooth pairing failed. (This message is
displayed when SSP authentication is
rejected by the host.)
Yes
Yes
28
WLAN FIRMWARE
UPDATING
○
Updating WLAN module firmware
No
No
29 WLAN CONFIG MODE
○
Set WLAN parameter by WEB browser
No
No
30 SETTING MODE
…
○
Setting mode.
No
No
Explanation of symbols
Symbol
Explanation
Range
○:
ON
-
△
:
Blinking(red)
-
:
Blinking
-
●:
OFF
-
xxxx
Remaining issue
0 to 9999 (in units of 1 label/tag)
####
Remaining memory capacity of PC save area in
the flash memory on the CPU
(*4)
0 to 3200 (in units of 1 Kbyte)
&&&&
Remaining memory capacity of writable
character/BASIC file/form/graphic storage area
in the flash memory on the CPU
(*4)
0 to 3200 (in units of 1 Kbyte)
‐‐
System error No.
00 to 21
$
Charge error No.
1 to 5
(*1) About version request and reset command, return version/reset after finishing SAVE
(*2) WAITING (MOTOR)
Motor protection control is a function to prevent motor failure arising from accumulated heat due to
continuous operations. This function monitors the motor operation ratio, and displays an error message on
the LCD and temporarily stops the motor if the ratio exceeds the specified threshold.