5.3 Remote throttle control (Cruise R)/ tiller (Cruise T) with integrated display
and magnetic key
5.3.1 Use of battery charge display when operating with Power 26-104 battery
5.3.1.1 Establishing communication between Power 26-104 and
Cruise outboards / Enumeration
Please check whether the batteries are physically existent and have all been switched
on. Commissioning only works if the system is able to communicate with the existing
batteries.
To establish communication between battery and outboard, a one-time calibration is
necessary.
Switch the main switch of your system to the ON position.
Push the ON/OFF button located below the screen of the remote throttle or tiller. Right
after (the screen is still „booting“ up and is showing „8“ in all segments), push the CAL
button (on some throttles called UNIT).
The screen will now change to ENU and display the start of the enumeration procedure.
The components establish the communication with each other automatically. The screen
will display the progress of the enumeration in percent and the number of detected bat-
teries.
After the process is completed, the progress counter shows 100% and the number of
connected batteries.
Switch off the entire system now. Motor and battery are now communicating directly
with each other. This enables you – among others – to look up the charge state of your
batteries on the display.
Please note the following: If you want to operate the Cruise with a different battery bank,
enumeration must be repeated. Otherwise, error E84 will be displayed.
Please be aware, that for older Cruise models, the communication between outboard and
Power 26-104 may not be available. Contact Torqeedo Service for questions.