g235610
Figure 29
1.
Relay
2.
Tether control box
Note:
Model 44554 machines have an additional 5 terminal relay located in the
tethered control box. This relay is not presently being used.
Testing the Relays
1. Park the machine on a level surface and stop the engine.
2. Disconnect the battery negative (-) cable at the battery.
3. Locate the relay to be tested and disconnect the wire harness connector from
the relay. Remove the relay from the control tower if necessary.
Note:
Before taking the small resistance readings with a digital multimeter,
short the multimeter test leads together. The meter displays a small
resistance value (usually 0.5 ohms or less). This resistance is because of the
internal resistance of the multimeter and test leads. Subtract this value from
the measured value of the component that you are testing.
g256780
Figure 30
4. Test the relay as follows:
Pro Force® Debris Blower
Page 5–25
Electrical System: Testing the Electrical Components
18237SL Rev A
Содержание Pro Force 44552
Страница 4: ...Reader Comments Page 4 Pro Force Debris Blower 18237SL Rev A ...
Страница 8: ...Preface Page 8 Pro Force Debris Blower 18237SL Rev A ...
Страница 28: ...Specifications and Maintenance Special Tools Page 2 14 Pro Force Debris Blower 18237SL Rev A ...
Страница 54: ...Engine Service and Repairs Page 4 16 Pro Force Debris Blower 18237SL Rev A ...
Страница 98: ...Electrical System Service and Repairs Page 5 44 Pro Force Debris Blower 18237SL Rev A ...
Страница 129: ...Pro Force Blower Drawing Rev Sheet 1 of 1 18237SL Rev A Page A 5 Engine Electrical Diagram g279585 ...
Страница 130: ...Page A 6 18237SL Rev A Pro Force Blower Drawing 122 1505 Rev A Sheet 1 of 1 Wire Harness Drawing Main g279710 ...
Страница 131: ...ProForce Blower Drawing 122 1505 Rev A Sheet 1 of 1 18237SL Rev A Page A 7 Wire Harness Diagram Main g279709 ...