![Toro OSMAC G3 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/toro/osmac-g3/osmac-g3_user-manual_1133827019.webp)
17
Seq Stations – Utilize this function to test all of the OSMAC G3 stations. To activate, navigate to On each for
and press Select
SELECT
SELECT
. Use the UP and DOWN
arrows to set the amount of time for each of the stations
to run, then press the RIGHT
arrow to activate. OSMAC G3 controller will continually sequence the stations
until the LEFT
arrow is pressed to cancel.
Specifications
Line Voltage: 115-120 or 230-240 V a.c. 50/60 Hz (switchable), 130 VA
Current Draw (no load): 0.21A @ 115-120 V a.c., 60 Hz or 0.10A @ 230-240 V a.c., 50 Hz
Current Draw (maximum load): 0.91A @ 115-120 V a.c., 60 Hz or 0.45A @ 230-240 V a.c., 50 Hz
Secondary Voltage Output: 24 V a.c., 50/60 Hz, 3.0A (85 VA)
Maximum Load Per Station Output: 0.75A (18 VA)
Maximum Load Per Pump/Master Valve Output: 1A (24 VA)
Operating Temperature: -10°C to +60°C (14°F to 140°F)
Storage Temperature: -30°C to +65°C (-22°F to 149°F)
Power Supply:
1.5A On/Off Switch/Circuit Breaker – Main Power Input
3.2A Fuse – Power Supply (Slow Blow)
4.0A Circuit Breaker – Control Functions
Control Modules:
Pump – 1.0A Fuse (Fast Blow, Automotive Type)
Station Output – 3.0A Fuse (Fast Blow, Automotive Type)