Comm Mode
- Select this menu to edit the OSMAC G3 controller’s communication mode.
Central Mode – When placed in Central mode, the OSMAC G3 satellite will wait and execute radio commands
sent by the central. The satellite will ignore all scheduled watering but will execute manual watering.
Local Mode – When placed in Local mode, the OSMAC G3 will execute scheduled watering as well as manual
watering. Radio commands will be ignored.
Off Mode – When placed in Off mode, the OSMAC G3 will not execute any watering operation whether it is
scheduled or manually initiated. Any watering operation will terminate once the satellite is placed in Off mode.
Watering operations will resume once the satellite is placed back to Central or Local mode.
Step 1 – While at the Home display, press Select
SELECT
SELECT
to access the controller menu.
Step 2 – Press DOWN
until Settings is selected and press Select
SELECT
SELECT
.
Step 3 – Press DOWN
until Comm Mode is selected and press Select
SELECT
SELECT
.
Step 4 – Use the UP and DOWN
arrows to select between Central, Local and Off modes.
Step 5 – Press Select
SELECT
SELECT
when the proper mode of operation is set.
What’s Running
Select this menu item to monitor the current watering activity of the OSMAC G3 controller.
Diagnostics
Menu:
Revision: 1.00
Rev Date: 4/21/16
Revision
Menu:
Clear log: No
Last code: 02, 002
01/02/16, 17:34:08
Event Codes
Menu:
RDV: 3.3 BV: 3.2
17V: 18.1 9V: 10.0
LCD: 31 C RSSV: 0.7
VA Monitor
Menu:
Sta: Pump
Press to start
Station Test
Menu:
On each for: 1 sec
Press to start
Seq Stations
Menu:
Defaults Set
Detect: 64sta, 00sen
PD 01/07/16 08:00:00
PU 01/01/16 12:00:01
Slot 1 card: Output
Power Detect
Revision – Displays the firmware’s version number and date it was created.
Event Codes – Displays diagnostic codes that the OSMAC G3 controller encountered. The codes could help Toro
troubleshoot your system. Clear the codes by navigating to Clear log, select Yes and press Select
SELECT
SELECT
.
VA Monitor – Displays the real time values of the following:
RDV - Radio Voltage
BV - Battery Voltage
17V - 17-volt Terminals
9V - 9-volt Terminals
LCD - LCD Voltage
RSSV - Signal Strength
Station Test – Utilize this function to test any of the OSMAC G3 controller outputs. You can activate the pump
and any stations by selecting Sta and press Select
SELECT
SELECT
. Use the UP and DOWN
arrows to select the
output terminal you want to test and press the RIGHT
arrow to activate. The station will remain activated
until you press the LEFT
arrow to turn off. While a station is active, you may test other stations by editing Sta
value.