Traction (Neutral) Switch Replacement (Fig. 25)
1. Remove the two wires that are connected to the
traction switch.
2. Loosen two (2) screws and remove the switch.
3. Install new switch. DO NOT over-tighten screws as
the switch case could break.
NOTE: Apply “Loctite 271” or equivalent to threads of
switch screws before installing.
4. Reconnect the two wires to the new switch. Make sure
that one wire is connected to the “COMMON” terminal,
and one wire is connected to the “NORMALLY OPEN”
(N.O.) terminal.
IMPORTANT: The traction switch has three (3) ter
minals. If the two (2) wires are not connected to the
Figure 25
“COMMON” and “NORMALLY OPEN” (N.O.) termi
nals, the engine will be unable to start and the safety
interlock circuit will not function properly.
TRACTION
NEUTRAL SWITCH
If the wires are not correctly installed to the
switch, the engine could start with the trac
tion pedal in forward or reverse.
CAUTION
5. Coat the switch terminals and wires with skin-over
grease.
6. Check traction control neutral adjustment. (See Trac-
tion Control Neutral Adjustment in the Adjustments sec-
tion of Chapter 4 - HYDRAULIC SYSTEM.
7. Actuate the pump lever to insure all parts are operat-
ing freely and seated properly.
8. Loosen jam nut. Rotate switch adjusting screw until
there is a gap between head of screw and switch button.
9. Rotate adjusting screw until it contacts the switch
button. Continue to rotate the screw until the circuit is
completed (switch “clicks”). After the switch clicks, ro-
tate the adjusting screw an additional 1/2 turn. Tighten
jam nut.
Repairs
Page 6 - 32
Groundsmaster
®
300 Series
Содержание Groundsmaster 328-D
Страница 2: ......
Страница 12: ...Torque Specifications Page 2 4 Rev A Groundsmaster 300 Series ...
Страница 44: ...Troubleshooting Page 4 16 Groundsmaster 300 Series ...
Страница 45: ...Groundsmaster 300 Series Page 4 17 Troubleshooting ...
Страница 58: ...This page is intentionally blank External Engine Components Repair Page 4 28 2 Rev D Groundsmaster 300 Series ...
Страница 143: ...Rev E Groundsmaster 300 Series Wiring Schematics Page 6 2 1 Groundmaster 345 Serial Number 40001 to 200999999 ...
Страница 145: ...Rev E Wiring Schematics Groundsmaster 300 Series Page 6 3 Groundmaster 322 D 325 D Serial Number less than 20000000 ...
Страница 171: ...Groundsmaster 300 Series Page 6 25 Testing ...
Страница 220: ...Repairs Page 7 24 Groundsmaster 300 Series ...
Страница 320: ...Troubleshooting Troubleshooting Page 11 4 Groundsmaster 300 Series ...
Страница 348: ...Troubleshooting Troubleshooting Page 12 4 Groundsmaster 300 Series ...
Страница 379: ...Troubleshooting Groundsmaster 300 Series Page 13 3 Troubleshooting ...
Страница 400: ...This page is blank ...
Страница 401: ...This page is blank ...
Страница 402: ...Commercial Products The Toro Company ...