Operation Problems
Condition
Possible Cause
Correction
Engine continues to run (but
Seat switch plunger depressed
Check for seat support spring
should not) when traction pedal is
with no operator on seat.
that is broken, missing or stuck in
depressed with no operator on
down position.
seat.
Check for binding seat pivot
hinge.
Check for waterlogged seat.
Seat switch faulty or out of
Test seat switch. Adjust or
adjustment.
replace if faulty.
Traction neutral switch faulty or out
Test switch, Adjust or replace if
of adjustment.
faulty. Check for correct terminal
connections.
Engine kills when traction pedal
Operator sitting too far forward on
Instruct operator.
is depressed or PTO is engaged.
seat (seat switch not depressed).
Seat hinge, support pin or spring
Repair seat pivot and support.
binding, preventing seat switch
from closing.
Seat switch is faulty or out of
Test seat switch. Adjust or
adjustment.
replace if faulty.
Seat switch wiring loose, corroded
Repair wiring.
or damaged.
Battery does not charge.
Loose, corroded or broken wire(s).
Repair wiring.
Faulty alternator.
Test alternator and replace if
faulty.
Dead battery.
Charge battery. Replace battery if
it will not hold a charge.
Battery continuously charges at
Regulator / rectifier faulty.
Replace regulator / rectifier.
high rate.
Groundsmaster
®
300 Series
Page 6 - 9
Troubleshooting
(Groundsmaster 345)
Содержание Groundsmaster 328-D
Страница 2: ......
Страница 12: ...Torque Specifications Page 2 4 Rev A Groundsmaster 300 Series ...
Страница 44: ...Troubleshooting Page 4 16 Groundsmaster 300 Series ...
Страница 45: ...Groundsmaster 300 Series Page 4 17 Troubleshooting ...
Страница 58: ...This page is intentionally blank External Engine Components Repair Page 4 28 2 Rev D Groundsmaster 300 Series ...
Страница 143: ...Rev E Groundsmaster 300 Series Wiring Schematics Page 6 2 1 Groundmaster 345 Serial Number 40001 to 200999999 ...
Страница 145: ...Rev E Wiring Schematics Groundsmaster 300 Series Page 6 3 Groundmaster 322 D 325 D Serial Number less than 20000000 ...
Страница 171: ...Groundsmaster 300 Series Page 6 25 Testing ...
Страница 220: ...Repairs Page 7 24 Groundsmaster 300 Series ...
Страница 320: ...Troubleshooting Troubleshooting Page 11 4 Groundsmaster 300 Series ...
Страница 348: ...Troubleshooting Troubleshooting Page 12 4 Groundsmaster 300 Series ...
Страница 379: ...Troubleshooting Groundsmaster 300 Series Page 13 3 Troubleshooting ...
Страница 400: ...This page is blank ...
Страница 401: ...This page is blank ...
Страница 402: ...Commercial Products The Toro Company ...