background image

Introduction

The FLX35-6 and FLX55-6 series full and part circle rotary 

sprinklers are designed specifically for golf course applications.

Manufactured from durable, high-strength engineering plastic and 

stainless-steel components, these sprinklers incorporate many 

innovative and time-proven features for lasting, maintenance-free 

operation. 
Prior to installing the sprinkler, read through the recommended 

installation and start-up procedures. Please observe all Warnings 

and Cautions when installing and operating this equipment.

Features

 

•  Adjustable Part circle (40°-330°) and true uni-directional full circle (360°) arc coverage

•  Arc adjustment in 5° increments

•  TruJectory

TM

 main nozzle trajectory adjustment from 7°-30° in 1° increments

•  TruJectory adjustment is graphically illustrated from the top

•  TruJectory is adjustable wet or dry 

•  Ratcheting riser in 2° increments

•  Nozzle base clutching

•  One back nozzle position

•  Industry’s largest precision nozzle selection

•  All nozzles are color coded, debris tolerant and threaded in from the front

•  Five electric and two hydraulic activation types

  o  Electric – Satellite systems – Standard 24 VAC solenoid; SPIKEGUARD 24VAC solenoid; Nickel plated    

 

 

      SPIKEGUARD 24VAC solenoid

  o  Electric – 2-wire systems – DC Latching solenoid; Integrated GDC module w/DC latching solenoid

  o  Hydraulic – Normally Open valve in head; Check-O-Matic (requires remote valve)

•  Constant velocity drive and variable stator provide consistent rotation speeds

•  Manual control at the sprinkler ON-OFF-AUTO (electric models only)

•  Selectable/lockable pressure regulation settings; 50 psi (3,4 bar), 65 psi (4,5 bar), 80 psi (5,5 bar) or 100 psi (6,9 bar)

•  Indestructable stainless steel valve seat and valve communication tube

•  Body inlet rock screen serviceable from the top

•  All internal components are serviceable from the top of the sprinkler

Specifications and Performance/Application Data

 

FLX35-6 Series

•  Radius: 42'–92' (12,8–28,1 m)

•  Flow Rate: 7.1–45.3 GPM  (26,9–171,5 LPM)

•  Trajectory: Selectable 7°–30°

•  Arc: Full Circle (360°) or adjustable part circle (40°–330°)

•  Recommended Operating Pressure:  

65–100 PSI (4,5–6,9 Bar)

•  Minimum Pressure: 40 PSI (2,8 Bar)

•  Maximum Pressure: 150 PSI (10,3 Bar)

•  Precipitation Rate: 

 

Minimum: 0.37"/hr (9,4 mm/hr) 

 

Maximum: 0.53"/hr (13,5 mm/hr)

•  Body Height: 10" (254 mm)

•  Pop-Up Height to Nozzle:  4 3/16" (106 mm)

•  Inlet Size: 1" (25 mm) NPT, BSP or ACME female thread inlet

•  Five electric activation types: 

Standard Solenoid - 24 VAC, 50/60 Hz,  

0.30 Amps Inrush, 0.20 Amps Holding 

SPIKEGUARD Solenoid - 24 VAC, 50/60 Hz,  

0.12 Amp Inrush, 0.10 Amp Holding 

Nickel Plated SPIKEGUARD Solenoid - 24 VAC, 50/60 Hz, 

0.12 Amp Inrush, 0.10 Amp Holding 

DC Latching Solenoid - Momentary Low Voltage Pulse 

Integrated GDC Module w/ DC Latching Solenoid - 

Momentary Low Voltage Pulse

•  Manual Control (Electric only): On-Off-Auto

•  Check-O-Matic Model checks up to 37' (11,2 m) of elevation  

•  Eight Nozzle Variations

FLX55-6 Series

•  Radius: 52'–100' (15,8–30,5 m)

•  Flow Rate: 13.9–61.1 GPM  (52,6–231,3 LPM)

•  Trajectory: Selectable 7°–30°

•  Arc: Full Circle (360°) or adjustable part circle (40°–330°)

•  Recommended Operating Pressure:  

65–100 PSI (4,5–6,9 Bar)

•  Minimum Pressure: 40 PSI (2,8 Bar)

•  Maximum Pressure: 150 PSI (10,3 Bar)

•  Precipitation Rate: 

 

Minimum: 0.43"/hr (10,9 mm/hr) 

 

Maximum: 0.60"/hr (15,2 mm/hr)

•  Body Height: 11" (289 mm)

•  Pop-Up Height to Nozzle:  4 3/16" (106 mm)

•  Inlet Size: 1.5" (40 mm) NPT, BSP or ACME

•  Five electric activation types: 

Standard Solenoid - 24 VAC, 50/60 Hz,  

0.30 Amps Inrush, 0.20 Amps Holding 

SPIKEGUARD Solenoid - 24 VAC, 50/60 Hz,  

0.12 Amp Inrush, 0.10 Amp Holding 

Nickel Plated SPIKEGUARD Solenoid - 24 VAC, 50/60 Hz, 

0.12 Amp Inrush, 0.10 Amp Holding 

DC Latching Solenoid - Momentary Low Voltage Pulse 

Integrated GDC Module w/ DC Latching Solenoid - 

Momentary Low Voltage Pulse

•  Manual Control (Electric only): On-Off-Auto

•  Check-O-Matic Model checks up to 37' (11,2 m) of elevation  

•  Nine Nozzle Variations

FLX35-6 & FLX55-6 Series Rotary Sprinklers

Installation and Service Instructions

Содержание FLX35-6 Series

Страница 1: ...and Performance Application Data FLX35 6 Series Radius 42 92 12 8 28 1 m Flow Rate 7 1 45 3 GPM 26 9 171 5 LPM Trajectory Selectable 7 30 Arc Full Circle 360 or adjustable part circle 40 330 Recommen...

Страница 2: ...Nozzle 80 PSI 46 2 GPM 59 Nozzle 80 PSI 53 3 GPM Trajectory 7 10 15 20 25 30 7 10 15 20 25 30 7 10 15 20 25 30 A Radius 72 74 77 83 89 85 75 77 83 87 92 88 77 78 84 89 96 92 B Spray Height 5 7 9 14 1...

Страница 3: ...102 2925 102 2910 102 2925 102 2910 PSI Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM 50 52 13 9 62 17 4 66 20 7 69 28 6 65 54 15 7 64 20 8 68 23...

Страница 4: ...deteriorate when exposed to moisture and earth ground causing shorts or open circuits resulting in improper system operation All direct burial wire connections must be done with approved waterproof co...

Страница 5: ...fter water has filled all lines and all air is removed remove the quick coupler keys Recommended System Fill Rate Pipe Size Flow Velocity Pipe Size Flow Velocity in cm GPM LPM ft sec m sec in cm GPM L...

Страница 6: ...area being irrigated Adjust by ratcheting the riser clockwise or counterclockwise until the sprinkler left stop points to the correct area See Figure 4 1 If the left stop falls short of the desired bo...

Страница 7: ...e The FLX35 6 and FLX55 6 sprinkler models are equipped with the TruJectoryTM nozzle spray angle adjustment feature The trajectory adjusts from the top of the sprinkler enabling fine tuning from 7 30...

Страница 8: ...ible equipment failures with causes and corrective action are listed below Sprinkler won t rotate Debris wedged between stator and turbine Remove obstruction Drive assembly defective Replace drive ass...

Страница 9: ...in valve Damaged or blocked valve seat Remove blockage and if necessary replace valve assembly Damaged piston seal or piston assembly Replace valve assembly Damaged pilot valve discharge seat Clean or...

Страница 10: ...en counterclockwise to remove Step 4 Remove the variable stator 14 from riser assembly Step 5 Remove the drive assembly retaining screw 12 and pull the drive assembly 13 using a pair of pliers See Fig...

Страница 11: ...l tool is not available use snap ring pliers to grasp rib of valve cylinder assembly and pull up and out of sprinkler body Step 3 Reinstall valve assembly using valve insertion tool P N 995 76 for FLX...

Страница 12: ...clockwise Step 7 Remove the retaining nut 18 and washer 17 from the pressure adjuster 11 and pull the pilot valve body assembly out of housing 16 Step 8 Remove diaphragm assembly 15 piston 14 spring 1...

Отзывы: