background image

Pilot Valve Operation (Electric Models Only)

 

The pilot valve controls the operation of the main valve located in the 

100 PSI 

(7.0 kg/cm

2

)

80 PSI 

(5.6 kg/cm

2

)

65 PSI 

(4.6 kg/cm

2

)

50 PSI (3.5 kg/cm

2

)

Figure 11

base of the sprinkler body. The main valve is operated by the release 

of water metered through the pilot valve when it is activated either 

manually at the sprinkler or by the irrigation system controller.

Another important function of the pilot valve is to regulate the water 

pressure to the sprinkler nozzle. Pressure regulation compensates 

for large variations within the system and maintains a constant 

pressure for optimum sprinkler operation. The pilot valve is factory 

set to regulate one of four pressure levels: 50 psi (3.5 bar), 65 psi 

(4.6 bar), 80 psi (5.6 bar) or 100 PSI (7.0 bar).

Change the pilot valve operating pressure by loosening the thumb 

screw that secures the selector lever. Position the selector lever to 

the desired operating pressure and hand-tighten the nut.  

See Figure 11.

Troubleshooting

 

Possible equipment failures with causes and corrective action are listed below.

Sprinkler won’t rotate

  – Debris wedged between stator and turbine

    • Remove obstruction

  – Drive assembly defective

    • Replace drive assembly

  – Nozzle base assembly defective

    • Replace riser assembly

Head sticks up 

  – Dirt in riser assembly

    • Flush out. (See Flushing Sprinklers)

  – Damaged or missing return spring

    • Replace

  – Damaged riser

    • Replace

Poor distribution pattern

  – Nozzle plugged with debris

    • Clean or replace nozzle

  – Nozzle orifice damaged

    • Replace nozzle

  – Low operating pressure

    • Determine why system overloaded and correct

Valve won’t close (Electric)

  – Continuous 24 VAC to sprinkler

    • Check controller for voltage source

  – Debris in Pilot Valve

    • Disassemble and remove all debris

  – Leak in pilot valve assembly

    • Replace pilot valve assembly

  – Plugged supply screen on piston

    • Clean or replace screen

  – Manual control selector on pilot valve assembly turned to “ON” position

    • Turn to “AUTO” position

  – Plunger movement restricted

    • Inspect and clean or replace

  – Valve cylinder misaligned with sprinkler body communication tube

    • Remove valve assembly and install correctly

  – Foreign object keeping valve from seating

    • Remove, clean and check valve for damage. Replace if necessary

Содержание FLX35-6 Series

Страница 1: ...and Performance Application Data FLX35 6 Series Radius 42 92 12 8 28 1 m Flow Rate 7 1 45 3 GPM 26 9 171 5 LPM Trajectory Selectable 7 30 Arc Full Circle 360 or adjustable part circle 40 330 Recommen...

Страница 2: ...Nozzle 80 PSI 46 2 GPM 59 Nozzle 80 PSI 53 3 GPM Trajectory 7 10 15 20 25 30 7 10 15 20 25 30 7 10 15 20 25 30 A Radius 72 74 77 83 89 85 75 77 83 87 92 88 77 78 84 89 96 92 B Spray Height 5 7 9 14 1...

Страница 3: ...102 2925 102 2910 102 2925 102 2910 PSI Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM 50 52 13 9 62 17 4 66 20 7 69 28 6 65 54 15 7 64 20 8 68 23...

Страница 4: ...deteriorate when exposed to moisture and earth ground causing shorts or open circuits resulting in improper system operation All direct burial wire connections must be done with approved waterproof co...

Страница 5: ...fter water has filled all lines and all air is removed remove the quick coupler keys Recommended System Fill Rate Pipe Size Flow Velocity Pipe Size Flow Velocity in cm GPM LPM ft sec m sec in cm GPM L...

Страница 6: ...area being irrigated Adjust by ratcheting the riser clockwise or counterclockwise until the sprinkler left stop points to the correct area See Figure 4 1 If the left stop falls short of the desired bo...

Страница 7: ...e The FLX35 6 and FLX55 6 sprinkler models are equipped with the TruJectoryTM nozzle spray angle adjustment feature The trajectory adjusts from the top of the sprinkler enabling fine tuning from 7 30...

Страница 8: ...ible equipment failures with causes and corrective action are listed below Sprinkler won t rotate Debris wedged between stator and turbine Remove obstruction Drive assembly defective Replace drive ass...

Страница 9: ...in valve Damaged or blocked valve seat Remove blockage and if necessary replace valve assembly Damaged piston seal or piston assembly Replace valve assembly Damaged pilot valve discharge seat Clean or...

Страница 10: ...en counterclockwise to remove Step 4 Remove the variable stator 14 from riser assembly Step 5 Remove the drive assembly retaining screw 12 and pull the drive assembly 13 using a pair of pliers See Fig...

Страница 11: ...l tool is not available use snap ring pliers to grasp rib of valve cylinder assembly and pull up and out of sprinkler body Step 3 Reinstall valve assembly using valve insertion tool P N 995 76 for FLX...

Страница 12: ...clockwise Step 7 Remove the retaining nut 18 and washer 17 from the pressure adjuster 11 and pull the pilot valve body assembly out of housing 16 Step 8 Remove diaphragm assembly 15 piston 14 spring 1...

Отзывы: