Maintenance
28
4.
Install the air cleaner cover and secure with the
knob (Fig. 24).
5.
Close the hood.
Servicing the Engine Oil
Change oil after the first 25 operating hours and then
every 100 operating hours thereafter.
Note:
Change oil more frequently when
operating conditions are extremely
dusty or sandy.
Oil Type: Detergent oil (API service SG or SH)
Crankcase Capacity: w/filter, 2.1 qt. (2 l)
Viscosity: See table below
F
–20
0
20
40
60
80
100
°
C
–30
°
–20
–10
0
10
20
30
40
USE THESE SAE VISCOSITY OILS
32
5W–20, 5W–30
10W–30, 10W–40
Changing the Oil
1.
Start the engine and let it run for five minutes.
This warms the oil so it drains better.
2.
Park the traction unit so that the drain side is
slightly lower than the opposite side to ensure
that the oil drains completely.
3.
Lower the loader arms, set the parking brake,
stop the engine, and remove the key.
POTENTIAL HAZARD
•
Components will be hot if the traction unit
has been running.
WHAT CAN HAPPEN
•
Touching hot components can cause burns.
HOW TO AVOID THE HAZARD
•
Allow the traction unit to cool before
performing maintenance or any touching
components.
4.
Remove the drain plug (Fig. 27).
1
m–4751
Figure 27
1.
Oil drain valve
5.
When the oil has drained completely, replace the
plug.
Note:
Dispose of the used oil at a certified
recycling center.
6.
Remove the oil fill cap and slowly pour
approximately 80% of the specified amount of
oil in through the valve cover.
7.
Check the oil level; refer to Checking the Oil
Level, page 12.
8.
Slowly add additional oil to bring the level to the
F (full) mark on the dipstick.
9.
Replace the fill cap.