Problem
Possible Cause
Corrective Action
1. The speed sensor is not calibrated
correctly.
1. Calibrate the speed sensor.
The Distance is inaccurate.
2. The speed sensor is damaged.
2. Contact your Authorized Service
Dealer.
1. The monitor cable is loose.
1. Connect the monitor cable.
2. The flow meter is dirty or clogged.
2. Clean the flow meter.
3. The flow meter is not calibrated
correctly.
3. Calibrate the flow meter.
The monitor does not display Application
Rate or Total Volume.
4. The flow meter is damaged.
4. Contact your Authorized Service
Dealer.
1. The flow meter is dirty or clogged.
1. Clean the flow meter.
2. The flow meter is not calibrated
correctly.
2. Calibrate the flow meter.
The Total Volume is inaccurate.
3. The flow meter is damaged.
3. Contact your Authorized Service
Dealer.
The monitor displays 6553.5 when in the
Application Rate setting.
1. The monitor is not receiving data from
the speed sensor.
1. Contact your Authorized Service
Dealer.
The monitor is erratic in operation.
1. A two-way radio is too close to the
monitor or its cables.
1. Keep two-way radios away from the
monitor and its cables.
The displayed measurements do not make
sense.
1. The Units of Measurement is set to a
system other than what you expect.
1. Check the Units of Measurement to
ensure that it is set correctly.
The monitor reads “OFL.”
1. The data has exceeded the maximum
allowed.
1. Press and hold the [Reset] button to
clear the monitor.
61