Charging System Removal (continued)
Figure 286
9. Remove the fuel tank from the engine.
10. Remove the 2 (10 mm) mounting bolts securing the charge coil to the
crankcase.
Figure 287
11. Remove the charge coil from the crankcase.
Alternator Test
1. Make sure the battery is fully charged.
2. Place the positive test lead from the volt meter to the positive terminal on
the mower battery.
3. Place the negative test lead from the volt meter to the negative test lead on
the battery.
4. Start the engine. Check the battery voltage. Voltage specification should be
13.2–16.2 VDC.
Electrical System: Service and Repairs
Page 8–18
1P65F-2 Service Manual
3429-270 Rev A