Inspecting and Cleaning the
Machine
When sweeping has been completed, thoroughly clean and
wash the machine. Air dry the hopper. After cleaning, inspect
the machine for possible damage to mechanical components.
Performing these procedures ensures that the machine will
perform satisfactorily during the next sweeping operation.
Transporting the Sweeper
•
Never transport the sweeper when the transport alarm
and the light are activated.
•
When transporting the sweeper, use the tie-downs to
secure the front of the machine (
) and the axle
(
) to secure the rear of the machine to the trailer.
Note:
Transporting the sweeper without using the
tie-downs could damage the machine.
Figure 29
1.
Front tie-downs
Figure 30
1.
Rear tie-down locations
Operating the Machine in Cold
Weather
The Workman high flow hydraulics oil must reach a operating
temperature of 82 degrees C (180 degrees F) for proper
operation of the floating sweeper head.
Switching the Sweeper-Up
Mode
The sweeper-up button has 2 possible modes; standard and
optional.
The standard mode allows the operator to raise the sweeper
to the pre-defined heights with a single button push. Refer to
Sweeper Up Button—Standard Mode (page 17)
The optional mode allows the operator to adjust the sweeper
to any desired height and it stops at the pre-defined heights.
Refer to
Sweeper Up Button—Optional Mode (page 17)
.
Use the following to switch the sweeper to the optional mode:
1.
Remove the cover off the control module.
2.
Unplug the 2 wire connections from the pigtail
connector show in
3.
Plug the 2 wire connections into the existing pigtail
connector tethered to the wiring harness.
4.
Install the cover onto the control module.
g030597
Figure 31
1.
Location of pigtails
3.
Standard-mode pigtail
2.
Optional-mode
pigtail—tethered to the
wiring hareness
Note:
To return to standard mode, install the original
pigtail connector.
25
Содержание 07068