INSTALLATION − DECO 7e / 10e − 0017
300440 en − 01/07
Chap. 4.5.2 /11
continuation
Activate the circuit-breaker on the autotransformer terminal box.
Turn on Main Switch QS0. see fig. 106
Check
XS1 service socket voltage
, see fig. 106
220V−240V
or US socket voltage
100V−110V ?
yes
2
Machine properly connected
1
4.5.2 Connecting Non-TORNOS Autotransformer
.
Caution !
The autotransformer is located outside the machine.
Machine
input terminal
box
see fig. 106
400V L1
400V L2
400V L3
50Hz
mains
input
For 50Hz mains
yes
no
50 Hz ?
Cut off mains supply.
Machine
input terminal
box
see fig. 106
460V L1
460V L2
460V L3
60Hz
mains
input
For 60Hz mains
Turn on Main Switch QS0 see fig. 106