Tornado Floorkeeper 28 OB/99128OB Скачать руководство пользователя страница 7

7

Scrubbers equipped with Hydralert™ technology have a sensor on the battery pack and an audio alarm 

which monitors and communicates low battery water conditions.

1. When batteries are fully charged and the key is turned on, Hydralert™ will check the water level

 

 •If the audio alarm is not activated, there is sufficient water in the batteries

 

 •An audio alarm means Hydralert™ senses a low battery water level. 

 NOTE

: Failure to clean the Hydralert™ light pipe will limit Hydralert™’s ability to read the water level    

 

and will reduce battery life.

2. Turn the key off and the fill the batteries with distilled water. (See WET, LEAD ACID BATTERY 

MAINTENANCE)

 NOTE

: Battery packs equipped with Hydralert™ may take more than ½ gallon of water after the  

 

 

Hydralert™ audio alarm has been activated. 

3. After completing the watering procedure, cycle the key to verify the audio alarm is not activated

CLEANING THE HYDRALERT™ SENSOR LIGHT PIPE

WARNING

: Battery posts, terminals, and related accessories contain lead and lead compounds, 

chemicals known to the State of California to cause cancer and reproductive harm, and during 

charging, strong inorganic acid mists containing sulfuric acid are evolved, a chemical known to the 

State of California to cause cancer. Wash hands after handling. For more information go to www.

P65Warnings.ca.gov

WARNING: 

Do not wear jewelry when working near electrical components

WARNING:

 Batteries emit hydrogen and oxygen gas

- Keep sparks and open flame away. Do not smoke near the machine

- Charge batteries in a well-ventilated area with the battery compartment open

CAUTION: 

Always wear protective clothing, gloves and goggles when handling and charging 

batteries

NOTE: 

Failure to clean the Hydralert™ light pipe will limit Hydralert™’s ability to read the water level 

and will reduce battery life

1.  Remove the cap with the black sensor module being careful not to damage the yellow floats. Do not 

remove the black sensor module from the cap assembly.

2.  Thoroughly wipe the clear light pipe next to the middle yellow float, paying extra attention to the tip of 

the pipe

3.  While the cap is still removed, cycle the key and verify the audio alarm activates. Turn the key off

4.  Carefully align the cap and press it firmly onto the battery making sure it is fully seated

5.  Complete the battery servicing procedures above, cycle the key, and verify the audio alarm is not 

activated.

6.  The machine is ready for use

An optional item is a Hydralert™ battery water monitoring system.  When the battery water falls below an 

accepatable level you will hear a audio alarm indicating the batteries need to be watered.

Содержание Floorkeeper 28 OB/99128OB

Страница 1: ...UMS FAX 817 551 0719 WWW TORNADOVAC COM Operations Maintenance Manual For Commercial Use Only Form No L9128AA 08 19 Tornado Industries LLC All rights reserved AUTOMATIC SCRUBBERS Floorkeeper 28 TD 991...

Страница 2: ...y Terms subject to change without notice 1 All Windshear Blowers Storm TV2SS Side and Downdraft Insulation Blowers CV 30 CV 38 CK14 1 PRO CK 14 1 BSE CK14 2 PRO SWM 31 9 CK LW13 1 CK LW 13 1 ROAM CV 3...

Страница 3: ...3 NOTES...

Страница 4: ...period the original receipt invoice will act as proof of purchase Contact Tornado for any warranty inquiries IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING THIS UNIT R...

Страница 5: ...ON Spinning brush Keep hands away Turn off power before working on machine CAUTION Do not operate machine unless trained and authorized NOTE Do not operate machine unless operator manual is read and u...

Страница 6: ...tance when lifting the machine NOTE Use a recommended ramp with a maximum of a 12 incline when loading or unloading into off truck or trailer NOTE When transporting the machine use tie down straps to...

Страница 7: ...ate of California to cause cancer Wash hands after handling For more information go to www P65Warnings ca gov WARNING Do not wear jewelry when working near electrical components WARNING Batteries emit...

Страница 8: ...ons and the weight are Width 7 1 8 in 181 mm Length 10 38 in 264 mm Height 11 5 8 in 295 mm Weight 72 lb 37 kg NOTE The on board charger has been programmed to work with the batteries that Tornado pro...

Страница 9: ...ed after the last yellow LED goes out leaving only red LEDs Using the unit beyond this point can reduce the life of the batteries NOTE The traction drive battery power level gage also displays fault c...

Страница 10: ...aintenance free AGM batteries As your unit leaves the factory the charger is set up to match the type of battery chosen in the original machine order Should you choose to change from the original batt...

Страница 11: ...he formation of excess foam could damage the vacuum motor so be sure to use only the correct amount of detergent Water temperature should not exceed 120 F 50 C 1 It is easy to gauge the solution level...

Страница 12: ...o position so that the unit s scrub head is centered over the pad driver s or brush es 3 Utilize the foot pedal to lower the scrub deck down onto the pad driver or brush by depressing the pedal while...

Страница 13: ...traditional cleaning pad first This pad acts as a backer pad which compensates for low and high spots in the floor 1 Align the Velcro pad retainer along one length of the red backer pad and press dow...

Страница 14: ...approximately 1 32 inch 1 mm off the ground allowing the recovery blade to deflect as shown below 2 If for some reason your squeegee blade height must be adjusted it is done so by turning the left thu...

Страница 15: ...ARGER DEBRIS DURING THE CLEANING PROCESS Your scrubber has been designed with two hooks molded into the handle that can be used to hang a plastic bag to put larger pieces of debris that you come acros...

Страница 16: ...sk units have settings of 70 110 and 150 lbs 32 50 and 65 kg The 28 orbital unit has setttings of 70 110 and 160 lbs 32 50 and 73 kg When the unit is set into operating position with the foot pedal it...

Страница 17: ...e feature allows the operator to lift the squeegee with the other hand a small element with big rewards when in tight spaces LOWERING THE SQUEEGEE To lower the squeegee lift the squeegee lever and shi...

Страница 18: ...while leaving the recovery hose attached lift the squeegee to a vertical position on the right side of the machine and place the squeegee tab into the squeegee hanger Squeegee assembly in transport p...

Страница 19: ...und scrub head for damage disk models only X Thoroughly clean entire machine X Check Bromine tablet Replace if it is 25 of the original size X Check linkages and connectors for wear damage X Check all...

Страница 20: ...can use a cleaner and sanitizer with a cloth or sponge to completely sanitize the recovery tank This reduces the mold and mildew that can form over time SQUEEGEE ASSEMBLY The squeegee system is cruci...

Страница 21: ...lly charged prior to watering Refer to the Charging segment of this manual for charging instructions Once charging is completed open the vent caps and look inside the fill wells Add distilled water un...

Страница 22: ...ry Connection Diagram After installation is complete be sure to charge your batteries before operating the machine NOTE If changing battery types from wet lead acid to AGM or vice versa see Machine Pr...

Страница 23: ...ntrasportingthemachine usetiedownstrapstosecurethemachinetothetruckortrailer NOTE Whentransportingthemachine putthescrubheadintheloweredposition Makesuretheunitisoffbeforedo ingso NOTE Donotallowtheor...

Страница 24: ...e Start by checking the recovery hose at the lower elbow connected to the squeegee assembly 2 Then check the upper elbow and the recovery tank orifice If debris is found clear the clog with your hands...

Страница 25: ...to consider the batteries If the batteries are wet lead acid batteries check the water levels in the battery cells If they require watering refer to the Battery Watering segment of this manual If the...

Страница 26: ...ocated on the underside of the unit between the wheels and the casters and clean out the debris Once clean re attach the filter and tighten it until snug Ensure the screen filter element is aligned pr...

Страница 27: ...triction collar then it is likely in the recovery tank at the drain opening In this case we suggest that the operator put rubber gloves on prior to submerging their hand to check for the clog Once the...

Страница 28: ...ng well short of this then it is likely that the recovery hose is not routed properly and has become an obstruction To fix this route the recovery hose to have the loop hose trap between the squeegee...

Страница 29: ...ueegee assembly may be obstructed Remove recovery hose and run water through it to check for any clogs Remove squeegee assembly and check for a clog in the neck of the assembly Recovery hose may be da...

Страница 30: ...on Squeegee is still in transport storage position Lower squeegee to operating position Vacuum motor relay may be faulty Contact a service center for testing Vacuum motor or wiring may be faulty Conta...

Страница 31: ...ree Traction drive motor tripped Remove overload condition and reset Traction drive motor has short circuited Contact a service center for testing Four Battery lockout has occurred Recharge batteries...

Страница 32: ...32 This page intentionally left blank...

Страница 33: ...cleaning and maintenance equipment o Contacted by local dealer o Previous experience with Tornado products o Reputation Recommendation o Advertising o Direct mail o Website ____________ o Blog _______...

Отзывы: