TROUBLESHOOTING GUIDE
ISSUE
POSSIBLE CAUSE
POSSIBLE SOLUTION
Insufficient water to the
brushes
Solution flow setting is too low
Make sure the solution control valve
is open by adjusting the solution flow
knob
Solution tank is empty
Check the sight gage for solution
level. If low or empty, add water and
detergent
Inline solution filter may be
clogged
Remove inline filter cap & screen to
check for clog. Rinse and put back in
place
Solution dispensing tubes may be
clogged, kinked or damaged
Visually inspect tubes
Ball valve at the outlet of the
soluiton tank is closed
Open valve.
Squeegee isn’t drying the
floor well
Squeegee blades may be dirty or
worn
Remove the squeegee assembly, rinse it
off and wipe the blades down. Inspect
edges for damage or wear. Flip or
replace blades as needed
Recovery hose may not be secure
at connections
Make sure upper recovery hose elbow
is secure at the recovery tank orifice.
Make sure that lower recovery hose
elbow is secure on squeegee assembly
neck
Recovery hose or squeegee
assembly may be obstructed
Remove recovery hose and run water
through it to check for any clogs.
Remove squeegee assembly and check
for a clog in the neck of the assembly
Recovery hose may be damaged
Check for damage. Replace if damage
found
Squeegee assembly height may be
out of adjustment
Check the squeegee height. See
Machine Preparation segment of
manual for squeegee height adjustment
instructions
Ball float may be damaged or
clogged and it is obstructing air
flow
Check to see that the ball float is moving
freely and is clean
Recovery tank is full
Empty recovery tank
Recovery tank lid is not sealing
Make sure that the lid is in the proper
position and that there isn’t damage to
the gasket. Replace gasket if damage
found
Drain hose cap may be loose
Make sure cap is clean and has been
pressed in tightly
Batteries may be discharged
Check battery indicator and if necessary,
recharge batteries
Machine will not turn on
Key switch may be faulty
Contact a service center to have tested
Batteries may be discharged
Charge your batteries until charger
indicates cycle is complete
Batteries may be faulty
Replace batteries
Battery cable(s) may be loose
Check connections and tighten if
necessary