EN - 65
4.9.6
Menu A: Set open time
Only in conjunction with function "Automatic close".
1. Select menu item "A".
ð
After approximately 2 seconds, the display flashes and shows the set
value of the operating mode.
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) but-
tons.
Value
Open time
0
0 s
1
10 s
2
30 s
3
60 s
4
90 s
5
120 s
6
150 s
7
180 s
8
210 s
9
240 s
3. Press the programming button (PROG button) (D).
ð
The value "H" is displayed.
4.9.7
Menu H: STOP-A settings
1. Select menu item "H".
ð
After approximately 2 seconds, the display flashes and shows the set
value of the operating mode. The factory setting is "0".
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) but-
tons.
Value
Description
Remarks
0
ENS-S 8200 or Extra 412 (with 8k2 resistor) connected to
STOP-A input (terminal G)
1
Jumper or ENS-S 1000 connected to STOP-A input (terminal G)
3. Press the programming button (PROG button) (D).
ð
The display shows "0". End of menu (if necessary, continue with power
learning cycle).
4.10
Completing the installation procedure
Close the cover of the drive head.
Check if the garage door operates properly and safely. See chapter "Mainten-
ance / Checks".