7: PROGRAMMING
©Tormach® 2020
Specifications subject to change without notice.
Page 56
UM10720: 1300PL Operator's Manual (Version 0820B)
For the most recent version, see tormach.com/support
7.1 PLASMA SPECIFIC G-CODES
Note:
For
information
on
all
other
supported
G-
and M-
codes,
refer
to
the
PathPilot
manual
at
tormach.com/support.
G-Code
Name
Description
G15
Workpiece
Probe
Probe vertically downwards towards the end of travel until the ohmic cap contacts the work piece.
Once the workpiece has been located, the Z coordinate of the current coordinate system is set to zero.
G15
will trigger on either the ohmic cap making continuity with the workpiece or the physical touch switch in
the torch lifter detecting upwards pressure on the torch from the material.
G16
Pierce
Raise the torch to the pierce height set in the variable #<_PierceHeight>. The torch is turned on and the
program pauses for the pierce delay value set by AutoFS or M209.
After the pierce delay, Torch Height Control (THC) is enabled and the program continues.
7.2 PLASMA SPECIFIC M-CODES
M-Code
Description
Set
by
M200
Parameters
M200
AutoFS - Apply the automatically generated feed, speed and cutting
values for the material selected in the main PathPilot UI. AutoFS will
set feedrate, THC voltage, and pierce delay.
M203
Start Torch
M205
Stop Torch and return to G30 Z Height
M207
Set Pierce Height used when executing a
G16
pierce. Set automatically
when using
M200
AutoFS.
Yes
P (Required): Pierce height in the current
unit system (in. or mm.)
M208
Set Cut Height used when executing a
G16
pierce. Set automatically
when using
M200
AutoFS.
Yes
P (Required): Cut height in the current
unit system (in. or mm.)
M209
Set Pierce Delay used when executing a
G16
pierce.
Set automatically when using
M200
AutoFS.
Yes
P (Required): Pierce delay in seconds
M210
Set THC voltage. Does not enable or disable THC.
Yes
P (Required): Desired THC Voltage
M211
Set plasma source cut current.
If a Hypertherm adapter is not installed on the system, program run
will be paused with an M01 break to allow the user to set the specified
cut current.
Yes
P (Required): Desired Cut Current in
Amps