CAL  Standard  Design 

SAFETY PRECAUTIONS 

 

  Before using this machine, be sure to read this “SAFTY PRECAUTIONS” and the 

appended “INSTRUCTION MANUAL” carefully for proper operation. 

  After reading through this paper, be sure to keep it in the place exposed to view at all time 

for operators. 

 

Concerning the safety precautions, this paper describes the contents of WARNING by the use 
of the following symbols and signs. 

 

Indicating the contents where a possibility of leading to serious results such as 
danger of injuries which persons may undergo in cases of mishandling due to 
neglect of this display is conceivable. 

Besides the above, the following WARNING label is affixed to the safety cover (coupling guard) of body coupling unit 

or its vicinity. 

 

The contents given below should always be following since any of them covers important note 
on safety. 

 

WARNING

 

1.  General 

1) 

Never allow any persons other than service engineers to engage in disassembly or repair, or remodeling work. 

2) 

Never work alone and be sure to put on helmet, safety goggles, ear plugs, safety shoes, etc. in conformity with the 

Labor Safety and Health Law, etc. 

3) 

Prior to carrying out any sparking work such as welding, etc., make sure that there are no dangers of fire and 

explosion hazards. 

4) 

Check the place where emission of toxic gas and deficiency of oxygen are conceivable, such as pit, manhole, etc. 

before starting on works and make sure of safety. 

5) 

When carrying out the work for centering check, disassembly, etc., be sure to turn OFF the motor switch and affix a 

tag indicating “NO POWER ON” or the like to the switch so that the switch will not be turned ON by mistake. 

6) 

Before starting on work, be sure to conduct checking of singing outfits such as crane, wire-rope. etc. unfailingly. 

7) 

Install safety fences around the working area and secure an emergency passageway. 

8) 

Since any splits oil on the floor, passageway, etc. may lead to a cause of slippage etc., wipe it off forthwith. 

 

Содержание CAL

Страница 1: ...PT TORISHIMA GUNA INDONESIA CAL END SUCTION...

Страница 2: ...allow any persons other than service engineers to engage in disassembly or repair or remodeling work 2 Never work alone and be sure to put on helmet safety goggles ear plugs safety shoes etc in confor...

Страница 3: ...t the specified position with mounting bolts 4 Maintenance 1 When carrying out the work for replacement of gland packing or mechanical seal be sure to turn OFF the motor switch and affix a tag indicat...

Страница 4: ...ge caused by the following 1 Operation of the pump under liquid quality density and temperature and running conditions which are deviated from those specified in the pump specifications 2 Pump damage...

Страница 5: ...rge nozzle and support foot The pump can be disassembled and internally inspected without removing the casing 1020 from the piping Refer to Table 0 1 for a representative Pump Sectional Drawing Table...

Страница 6: ...conditions refer to Section 6 P 21 Fig 0 4 2 Sectional Drawing gland packing grease lubrication Note 1 The above figure is one structural example Note 2 The structure of mechanical seal is different...

Страница 7: ...g 3300 0 4 5 Shaft The shaft components of each pump type are interchangeable with those of other pump As shown in Table 0 2 the shaft is available in six sizes which cover all models of the CAL pumps...

Страница 8: ...side 2 To check the rotational direction of the motor with the pump that uses a flanged flexible shaft joint remove the coupling bolts With the pump that uses a rubber shaft joint slide the couplings...

Страница 9: ...e installation be sure to check the following items for normality prior to starting If abnormality de found upon checking take corrective actions in accordance with the Troubleshooting Instructions gi...

Страница 10: ...nning And is the discharge valve kept closed 6 Is each bearing free from abnormal temperature rise 3 2 Shaft seal 3 2 1 In the case of mechanical seal type It is one outstanding feature of mechanical...

Страница 11: ...mounted to the discharge piping These pressure gauges must be provided with gradations capable of covering about 150 of maximum operating pressure Also connect a gauge cock to each gauge When pumping...

Страница 12: ...will remove dirt well When a new bearing is used replace all amount of lubricating oil after operation for the initial 300 hours After that the replacement interval should be 3 000 hours of operation...

Страница 13: ...ue is 1 0 mm The design value for the impeller whose material is SCS is 0 6 mm and the tolerance value is 1 2 mm If the tolerance value is exceeded replace the case wearing ring 3 6 When the pump is l...

Страница 14: ...ling and reassembling When rubber shaft joint is used When flanged flexible shaft joint is used The above figure shows an example of pump and motor configuration The type of configuration varies depen...

Страница 15: ...r wear and other damage of the element If an abnormal condition is found replace the element with a new one 13 Remove the both bearing covers 3600 from the bearing housing 14 Slowly pull the shaft out...

Страница 16: ...mp Including the running under the seal box pressure below the atmospheric bar Dry running will result in seizure trouble of the mechanical seal eventually causing not only the mechanical seal but als...

Страница 17: ...32 45 Fig 5 2 1 Construction of mechanical seal CA Note For order of additional spare parts designate the type of the mechanical seal as a set in order to ensure preferable seal effect Parts table of...

Страница 18: ...710 Seal cover 4751 Seat holder Unit mm Shaft size 25 360 24 44 5 35 470 45 470 45 470A 55 530 65 530 55 52 5 32 45 53 49 5 Fig 5 2 3 Construction of mechanical seal LTW Conforming to DIN 24960 standa...

Страница 19: ...Shaft size 25 360 24 37 35 470 45 470 45 470A 55 530 65 530 55 39 5 32 45 39 40 Fig 5 2 5 Construction of mechanical seal L9SA SiC SiC Conforming to DIN 24960 standard Note For order of additional sp...

Страница 20: ...et water cooling In case a jacket water cooling type refer to Fig 5 2 9 Do not use the liquid with a strong causticity for cooling water because the material of the jacket cover 1650 is a cast iron Th...

Страница 21: ...cautions Refer to the disassembling procedure for the type of the mechanical seal being used A Single mechanical seal Type CA 1 After completion of the disassembling steps 4 2 1 4 2 8 P 12 pull the ro...

Страница 22: ...the casing cover mount the casing cover to the bearing housing 3300 When mounting the casing cover to the bearing case use caution so as not to break the seat and not to damage the internal surface o...

Страница 23: ...the fixed side mounted to the seal cover put the O ring 4120 3 in the seal cover Fit the seal cover on the shaft 2100 and slide the seal cover toward the bearing housing 3300 When mounting the seal co...

Страница 24: ...k In case where external flushing is continued even while the pump is not in operation in order to prevent air intake Pumping of clean high temperature liquid at suction pressure higher than atmospher...

Страница 25: ...een sliding parts as necessary Ingestion of air from stuffing box Increase the sealing water pressure and check if sealing water normally flows Clean inside of the sealing water piping if necessary If...

Отзывы: