Checks and repairs on hydraulic components
72
Checking the low-pressure cut off valve
WARNING
Slipping hazard from leaked oil.
Bruising and bone fractures possible.
Clean up any leaked oil with a cloth or suitable binding
agents.
Wear safety shoes with non-slip soles.
CAUTION
Health hazard from contact with hydraulic oil.
Wear nitrile gloves and chemical-resistant protective
goggles during work that may include contact with
hydraulic oil.
To check the low-pressure cut off valve, proceed as follows:
Move the unit into the repair position for the upper structures, see from
page 51.
Remove the carrying handle, see from page 50.
Mount the protective caps and protective plugs of the couplings, see from
page 49.
Release the screw connections (A) on the cover with two combination
wrenches WAF 10, as described in the chapter “Moving the unit into the
repair position for t
he lower structures”, see from page