TOPVERT G1/H1/P1 Series
E-12
AO1
Multi-Function analog output 1
(can output DC 0~10V voltage signal)
Max.2mA/Pr3-15/
(Output frequency)
AO2
Multi-Function analog output 2 (current signal or
voltage signal selectable)
(when AO2 analog output selector switch to “V”
can output DC 0~10V voltage signal. when
switch to “I” can output DC 4(0)~20mA current
signal.
Pr3-16/(4~20mA )
(Output frequency)
[AO3]
[Multi-Function analog output 3]
(can output DC 4(0)~20mA current signal)
Pr3-15/(4~20mA )
(Output frequency)
Digital outputs and serial port
(Use the shielded twisted-pair cables to prevent operating faults)
MO1
Multi-Function Digital output 3 - MO1
Max.48VDC,50mA/( Pre-set speed
attained 1 (Forward only) )
MO2
Multi-Function Digital output 4 – MO2
Max.48VDC,50mA/
( Drive ready for use)
MCM
Multi-function output terminal – the common end
SG+
RS-485 serial port +
SG-
RS-485 serial port -
[MO3] [Multi-Function Digital output 5 MO3+]
Pr2-24
[MC3] [Multi-Function Digital output 5 MO3-]
[MO4] [Multi-Function Digital output 6 MO4+]
Pr2-25
[MC4] [Multi-Function Digital output 6 MO4-]
[ ]:Option
Description of the Digital Keypad
Digital Keypad PU-01 function descriptions
FWD
REV
EXT
PU
Part number
Status Display
……
……
……
……
Display the driver's current status
When "PU" lights, RUN/STOP is controlled by PU-01.
When "PU" is dark, RUN/STOP is set by Pr0-19.
When "EXT" lights, frequency command is set by Pr0-18.
When "EXT" is dark,frequency command is controlled by PU-01
When "REV" lights, Drive is in reverse operation.
When "FWD" lights, Drive is in forward operation.
Left /Reset key
Moves cursor to the left.
Reset errors.
FWD/REV
Direction key
Display Selection key
Changes between different display mode.
STOP key
Programming Unit key
Enable the keypad.
It can determine the source of RUNSTOP
RUN key
PU-01
PU
JOG
DISP
F/R
RUN
STOP
RUN indication
STOP indication
RESET
Main Display
Display t
he drive status such as
frequency,
current, voltage,
parameter
setting valueand
alarm contents.
Data modification/Program Dial
Rotate to modification for settings, parameters
and output frequency adjustment.
Press to Read or Enter datas
Jog Operation key
Press this key to execute JOG frequency opeation