background image

POWERED FLOW-THROUGH HUMIDIFIER

3

68-3074—01

Fig. 3. Humidifier location in relation to air conditioning coils.

Fig. 4. Humidifier components.

Fig. 5. Position securing clips.

7.

Position the humidifier housing in the hole (be sure it is 

level), so the locking tabs are in place on the upper and 

lower sheet metal edges of the hole. 

8.

Push in the securing clips until completely seated.

9.

Drill holes and install the three sheet metal screws at the 

top of the humidifier housing. Secure the housing with 

the three remaining screws at the bottom of the housing.

10.

Reinstall the humidifier pad assembly in the humidifier 

housing.

IMPORTANT

For proper operation, be sure the mark on the end of 

the humidifier pad is facing up. Check that the water 

feed tube is placed in the guide slots of the humidifier 

housing.

11.

Hook the top of the cover to the housing and secure with 

the thumbscrew located at the bottom of the cover.

WIRING HUMIDIFIER

WARNING

Serious Personal Injury or Equipment Hazard. 

Moving parts can cause electrical shock and injury.

• Disconnect power supply before installation or 

servicing.

• This device contains a moving fan blade; do not 

operate the humidifier without the cover securely 

attached.

All wiring must comply with applicable local codes, ordinances 

and regulations.

For Convertible Humidity Control Wiring 
Connections:

IMPORTANT

• Select models of fan centers include humidifier taps 

so the current sensing relay or sail switch is not 

needed.

• If not using a current sensing relay or sail switch, the 

120V humidifier plug must be energized during 

blower motor cycles for proper operation.

1.

Wire the current sensing relay or sail switch.

2.

Connect only the two yellow wires to the humidity control 

(red wire connections are not used for mechanical 

humidity control). See the typical wiring diagrams in Fig. 

6 through 8.

For additional mounting and wiring information, refer to the 

humidity control installation instructions.

Fig. 6. Typical wiring diagram for humidifier using fan 

control to cycle blower motor fan and humidifier 

simultaneously.

Fig. 7. Typical wiring diagram of current sensing relay with 

humidifier.

M12812

M28929

COVER 

ASSEMBLY

HUMIDIFIER 

PAD ASSEMBLY

FEED TUBE NOZZLE

WATER 

DISTRIBUTION TRAY

HUMIDIFIER

HOUSING

THUMB 

SCREW

M12813

CLIP

CLIP

HUMIDIFIER

MECHANICAL
HUMIDISTAT

120 VAC

TO BLOWER
MOTOR
IGNITION BOX

M12686

YELLOW WIRES

1

1

2

2

POWER SUPPLY.  PROVIDE DISCONNECT MEANS AND 
OVERLOAD PROTECTION AS REQUIRED.

24V WIRING.

CURRENT
SENSING
RELAY

HUMIDIFIER

120 VAC

BLOWER 
MOTOR

C

LO

HI

M12684

YELLOW WIRES

1

1

2

2

POWER SUPPLY.  
PROVIDE DISCONNECT
MEANS AND OVERLOAD 
PROTECTION AS REQUIRED.

24V WIRING.

MECHANICAL
HUMIDISTAT

Содержание TT-HUM-365

Страница 1: ...T The specifications given in this publication do not include normal manufacturing tolerances Therefore this unit may not exactly match the listed specifica tions Also this product is tested and calib...

Страница 2: ...ure is between 32 F 0 C and 160 F 71 C Do not install where freezing temperatures could occur Be sure supply plenum static pressure is no greater than 0 4 in wc and water pressure is no greater than 1...

Страница 3: ...with applicable local codes ordinances and regulations For Convertible Humidity Control Wiring Connections IMPORTANT Select models of fan centers include humidifier taps so the current sensing relay o...

Страница 4: ...the Convertible Humidity Control The convertible humidity control is installed either on an interior wall in the living area or on the return air duct Choose the humidity control setting using the com...

Страница 5: ...ing if necessary 11 Bend the drain hose to loosen any mineral deposits 12 Flush the drain hose with pressurized water a running tap to clean the hose 13 Reattach the drain hose to the drain fitting 14...

Страница 6: ...ower is on Check all external wiring connections Check the humidity control setting Call a professional heating contractor Rapid air changes Drafts cold air is dry and is an added load to the humidifi...

Страница 7: ...POWERED FLOW THROUGH HUMIDIFIER 7 68 3074 01 Fig 10 Key to Replacement Parts 1 M28931 2 5 3 6 4...

Страница 8: ...POWERED FLOW THROUGH HUMIDIFIER U S Registered Trademark 2010 68 3074 01 M S 08 10 Printed in U S A...

Отзывы: