Maximum Power Voltage - Vmp (V)
35.40
35.60
35.80
Maximum Power Current - Imp (A)
7.91
8.01
8.11
Open Circuit Voltage - Voc (V)
44.10
44.20
44.30
Short Circuit Current - Isc (A)
8.57
8.62
8.67
Maximum Power - Pmax (W)
28 0
285
290
Maximum Series Fuse (A)
16
Max-System Voltage (VDC)
1000
Dimensions (mm)
1956*992*50
Weight (kg)
23
Topray Solar crystalline solar modules has two 4mm
2
diameter type standard 90°C sunlight resistant output cables each
terminated with plug & play connectors. This cable is suitable for applica ons where wiring is exposed to the direct rays of
the Sun. For a series electrical connec on, connect posi
(+) connector of
ĮƌƐƚ
module to the
(-) connector of
the second module.
All wiring should be completed in accordance with all applicable state and local electrical codes. During system design,
Short-Circuit Current (Isc) and Open-Circuit Voltage (Voc) should be mul plied by a factor of 1.25 to determine component
voltage
, conductor ampacity, fuse ra ng and the size of the controls connected to the modules or system output.
Topray Solar suggests that every series module string should be fused prior to be connected with other strings. Please
refer to the applicable regional and local codes for addi
fuse requirements. When necessary, please install blocking
diodes to protect modules or system been damaged by reverse current.
Do not short the po
and the nega ve of a single module. Do not disconnect under load. Be sure connectors have no
gap between the insulators. A gap can cause
Į
re hazard and/or danger of an electrical shock.
All Topray Solar crystalline solar module frames and mo
racks must be properly grounded in accordance with the
appropriate
na onal electrical code. Proper grounding is achieved by conn
the module frame(s) and
structural members con
uously one to another using a suitable grounding conductor. Holes provided for this purpose on
the module frame are
d in chart 4. The grounding conductor or strap may be copper, copper alloy, or other
material acceptable for use as an electrical conductor per resp
nal Electrical Codes. The grounding conductor
must then make a conn
on to earth using a suitable earth ground electrode.
a separate conductor as grounding wire to one of the 6mm diameter grounding holes on the module frame as
Į
ed in Figure 6 with a set of M6 screw, cup washer,
Ň
at washer, tooth washer, and M6 nut. Please note that a star
13
36.00
8.20
44.50
8.74
295
TPSP6U-280W
TPSP6U-285W
TPSP6U-290W
TPSP6U-295W
P6U
8