* required only in case of FULL ENERGY mode
Verify the sensor configuration directly in the sensors’ manual
SENSORS POSITIONING
REVERSE THE ELECTRONIC GROUP
ELECTRONIC BOARD DIP-SWITCHES SETTING
BEFORE STARTING THE INSTALLATION
Check the following points:
•
The structure that will support the automation is sufficiently sturdy
•
Surface on which the actuator bracket will be fastened is free of distortions.
•
Care has been taken to eliminate protruding parts of the door
•
Care has been taken to eliminate any sharp and/or pointed parts of the door
•
The wing can move freely and without hindrance or friction.
•
The wing is rigid and sturdy. The hinges are adequate and in good conditions.
•
The door has a mechanical stop in opening (not supplied) (see Figure Ref. 1) 3 cm further
than the maximum desired opening position.
•
The door closes firmly and smoothly.
•
The power supply cables and the control cables for the sensors and/or related accesso
-
ries have been prepared.
•
If necessary, in case of installation with rotation axis (hinge) on the right side. invert the
electronic unit, as described below.
VERIFY
Before installation check the amplitude of passage, the direction of door opening, the side on
which the automation will be installed, the overlap of the architrave, the vertical space between
the automation and arm.
Orthogonality-parallelism of the enveloped surfaces.
instructions for installation
M200
PRELIMINARY OPERATIONS
Содержание M200
Страница 20: ...M200 20 instructions for installation LIST OF ERROR MESSAGES AND NOTICES ...
Страница 28: ...M200 28 instructions for installation EC DECLARATION OF INCORPORATION ...
Страница 29: ...29 instructions for installation M200 ...
Страница 30: ...M200 30 instructions for installation ...
Страница 31: ...31 instructions for installation M200 ...