![TOPP K500 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/topp/k500/k500_instructions-for-installation-and-use-manual_1129578036.webp)
Warnings are displayed every five seconds for one second.
Every error is reset during the reset/learning stage or by switching off the equipment.
5.8
SELF RESTORE MANAGEMENT OF ERRORS C-D-E-K-N-P-Q
Ÿ
Zeroing (near) fails order -> automation performs a new attempt to reset (near) that is repeated for the number 5
consecutive times;
Ÿ
During the slow opening in the preceding paragraph, the occupation of the side sensors causes a slow reclosing
Ÿ
Zeroing (near) is successful -> automation continues to work properly;
Ÿ
Additional 2 resets not complete successfully -> automation finally stops in error and you will need the intervention
of a qualified technician.
During the zeroing phase (near) the safety sensors are active, and if:
Errors
C-D-K-N-P-Q
cause a momentary arrest of automation, pending the launch of the procedure for restoring
normal operation.
The procedure involves the automatic execution of a reset command (near) and will be carried out as follows:
Ÿ
The 5 attempts are successful -> automation opens and remains stationary in the open for 5 minutes and then
repeated two more attempts to reset at intervals of 5 minutes;
Ÿ
During the slow closing, the employment of safety sensors of the transit space commands a reopening slow.
Ÿ
During the movement, the contemporary employment of at least one safety sensor side and a sensor safety
compartment passage controls the stop of the door.
Battery not installed. Check connector.
Description
Motor prevented by obstacle from opening. Check for obstacles or friction.
Motor prevented by obstacle from closing. Check for obstacles or friction.
S
t
U
V
W
Clock malfunction/not adjust. Set the exact time.
Motor bridge voltage low.
Motor bridge voltage high. The door operates: the LED flashes
Q
r
Inside warning. Check for any short cirtuiti peripherals.
Antipanic alarm actived
Internal safety.
X
Z
R
Motor over-temperature
Display
code 7
Code-error list
( switch)
segments
36