PROGRAMMING PARAMETERS ON THE K500
ENTER
DOWN
Code
Description
Parameters set from digital switch
Presence of electric lock ( without dot=electric lock not present )
Presence of battery ( without dot=battery present)
Partial opening (without dot=not disabled =70%, with dot=enabled =40%)
Seal on closure ( without dot=not disabled=0; with dot=enabled=Level 2 )
Automatic and partial reclosing time ( without dot=disabled=5 ; with dot=enabled=0 )
Opening speed adjustment at 45cm/sec and closure at 25cm/s
Opening/closing speed increase at 45cm/s
Opening speed increase at 65cm/s and closure at 35cm/s
Press and hold <ENTER> for 5 sec to enter the configuration menu.
Press <DOWN> to pass from a parameter to another, press <ENTER> to enable/disable the
function.
It is possible to enter the basic parameters using the 7 segment display and the <ENTER> and
<DOWN> keys.
The presence on the display of a dot next to a parameter code indicates that the function is
enabled.
WITHOUT DOT-monitored sensors (with test) type Optex OA-Axist T or
Hotron HR100_CT
WITH DOT-NC not monitored sensors (without test connection)
Safety logic:
Don’t used
(Allows the use of "Wings free", if the automation board is set up for the "Wings free", function)
Change the operating mode of the buttons for TS1, TS2 and MS1 in ”WINGS FREE”
operation mode ( with dot=enabled ; without dot=disabled )
If the
MS1
program selection knob is available, selecting “Enter only” , “Wings Free” operation mode is activated.
Pressing the button “Open” for more than 10 seconds, the “Open” operation mode activates.
If the
TS2
remote control is available, pressing the button “Enter only” ,“Wings Free” operation mode is activated.
If the
TS1
remote control is available, pressing the button “Open” , “Wings Free” operation mode is activated.
Description of behavior / y parameter = with dot
To program the radio control devices (up to 8):
display.
To confirm that the remote control has been memorized, the "Radio" character sequence will no longer be displayed.
1. Press the “DOWN” key and hold for 5 seconds. The sequence of characters “Radio” appears on the 7-segment
2. If you have the Topp remote control
TS2
press the smooth side of the first key (open function).
If the Topp
TS1 4-
channel remote control is available, press the second key (Close Function).
To deactivate all radio control devices:
2. Press the “DOWN” key and hold for a further 5 seconds, all remote controls connected to the electronic board will be
deactivated.
To confirm that all programmed remote controls have been deactivated, the sequence of characters "Radio" will no longer be
displayed.
1. Press the “DOWN” key and hold for 5 seconds, then release it. The sequence of characters “Radio” appears on the 7- segment
display.
34
INSTRUCTIONS FOR INSTALLATION AND USE
EN
K500
Содержание K500
Страница 2: ......
Страница 42: ...42 INSTRUCTIONS FOR INSTALLATION AND USE EN K500 ...
Страница 43: ......