Tab. 1
contains the technical data characterising the actuators.
230 V ~ 50 Hz
C15/230V
0,12 A
300 N
200 N
8 mm/s
17 s
C15/24V
0,43 A
7,5 mm/s
18 s
Power supply voltage
Absorbed current
Absorbed power with load
Thrust force
Tractive force
Idle translation speed
Duration of the idle stroke (
mm)
135
24 V
(1)
Minimum window frame height
Limit switch: Electronic for opening - by amperometric absorption for closing
Protection against electric shock
(3)
Type of service S
2
Class II
4 min
Operating temperature
Protection degree of electric devices
Adjustment of the window frame connection
Parallel electric connection of more
actuators on the same window
Parallel electric connection of more
actuators on different windows
Actuator weight with brackets
Gross weight
- 5 ºC + 50 ºC
IP 30
NO
YES
(see wiring diagram)
NO
0,97 kg
1,15 kg
Class III
Tab.1
3.3
TECHNICAL DATA
9 W
25 W
(1)
Actuator distance from the window frame opening hinge
(2)
Tolerance on the precision of the output limit switch tripping: +/- 2 cm
(3)
Service of limited duration according to EN 60034
-
+
1
2
1)
Switch l
=120mm
Switch ll
=240mm
2)
Dip
switch
Min
(-)
Max
(+)
150 N
100 N
200 N
300 N
Dip switch power
Thrust force
Tractive force
13
INSTALLATION AND USE INSTRUCTIONS
C15
EN
200
Top hung
Bottom hung
300
350
3.4
DESTINATION OF USE
The actuator has been designed and manufactured
to perform, by means of a command device, the
opening and closing of top hung windows, bottom
hung windows, pivot windows, and skylights.
3.5
USE LIMITS
The actuator has been designed and manufactured
exclusively for the destination of use given in
par. 3.5
,
therefore, any other type of use is strictly forbidden in
order to assure in any moment the safety of the installer
and of the user, as well as the efficiency of the actuator
itself.
Operation stroke length
I=120mm II=240mm